6004 Call Denial On Line Or Hunt Group (Pacific Bell Region Specific)

This screening option limits terminating Circuit Switched Line calls to
completion within the LATA where the Circuit Switched Line resides.  InterLATA
and International calls are blocked, as well as calls which may potentially
terminate outside the LATA.  The Caoll Denial option allows calls to terminate
to any NXX within the LATA served by the Circuit Switched Line that does not
have a special charge associated with it.  Blocked calls are routed to a
reorder tone or recorded announcement.

Call Denial On Line Or Hunt Group is useful to 900 services and the ESP
industry for fraud control.

This feature is provided in all electronic end offices and, where available,
in electro-mechanical end offices.

Generic Name of ONA Service
 	Product Name				BSE or CNS
============================================================================
Call Denial On Line Or Hunt Group
	PB - Call Denial On Line Or Hunt Group	BSE

Reference: TR-NPL-000334, Issue 1, June 1986.

This service, if offered as a BSE, is associated with the Circuit Switched
Line basic serving arrangement.