;;               CAKEWALK System Exclusive Dump Request Macros
;;========================================================================;;
;;
;; Device  : Roland U-220 RS-PCM Sound Module 
;; Version : Cakewalk 4.0E
;; Author  : Bee Tree Studio   CompuServe  74040,2342

;; Format  : Byte   Description
;;           F0H    Exclusive
;;           41H    Manufacturer (Roland)
;;           10H    Device ID   
;;           2BH    Model ID
;;           11H    Command ID 
;;           aaH    Address MSB
;;            .
;;            .     Address LSB
;;           ssH    Size MSB
;;            .
;;            .     Size LSB
;;           sum    Check sum
;;           F7H    End of exclusive

;; Notes   : U220 DRM's are divided into two sections,      
;;             . Bulk Dump Areas
;;             . Individual Parameter Control Area
;;           DRM titles correspond to the descriptions used in the MIDI
;;           implementaion section of the U220 Owners Manual (pg 146).
;;           DRM's are not included for the Rhythm Instrument Setup,
;;           addresses 11 23 00 thru 11 63 00 as they appeared to be     
;;           relatively useless.                       
;;                               
;;                                                 Address  Size     Sum 
;;----Bulk Dump Areas                              -------- -------- --
"U220 Bulk Dump Setup Parm       "  F0 41 10 2B 11 00 00 00 00 00 10 70 F7
"U220 Bulk Dump Patch Temp       "  F0 41 10 2B 11 00 06 00 00 01 20 59 F7
"U220 Bulk Dump Timbre[1]    temp"  F0 41 10 2B 11 00 10 00 00 00 40 30 F7
"U220 Bulk Dump Timbre[2]    temp"  F0 41 10 2B 11 00 11 00 00 00 40 2F F7
"U220 Bulk Dump Timbre[3]    temp"  F0 41 10 2B 11 00 12 00 00 00 40 2E F7
"U220 Bulk Dump Timbre[4]    temp"  F0 41 10 2B 11 00 13 00 00 00 40 2D F7
"U220 Bulk Dump Timbre[5]    temp"  F0 41 10 2B 11 00 14 00 00 00 40 2C F7
"U220 Bulk Dump Timbre[6]    temp"  F0 41 10 2B 11 00 15 00 00 00 40 2B F7
"U220 Bulk Dump Rhythm Setup temp"  F0 41 10 2B 11 00 20 00 00 0C 20 34 F7
"U220 Bulk Dump Timbre           "  F0 41 10 2B 11 02 00 00 00 40 00 3E F7
"U220 Bulk Dump Patch            "  F0 41 10 2B 11 03 00 00 00 50 00 2D F7
"U220 Bulk Dump Rhythm Setup     "  F0 41 10 2B 11 05 00 00 00 31 00 4A F7
"U220 Bulk Dump Patch Map        "  F0 41 10 2B 11 07 00 00 00 08 00 71 F7
"U220 Bulk Dump Timbre Map       "  F0 41 10 2B 11 07 08 00 00 08 00 69 F7
"U220 Bulk Dump Rhythm Map       "  F0 41 10 2B 11 07 10 00 00 08 00 61 F7
"U220 Bulk Dump Rhythm Inst. Map "  F0 41 10 2B 11 07 18 00 00 08 00 59 F7
;;                
;;                                                 Address  Size     Sum 
;;----Individual Parameter Control Area            -------- -------- --
"U220 Setup Parameter            "  F0 41 10 2B 11 10 00 00 00 00 03 6D F7
"U220 Patch Common               "  F0 41 10 2B 11 10 04 00 00 00 29 43 F7
"U220 Patch Rhythm Part          "  F0 41 10 2B 11 10 04 60 00 00 07 05 F7
"U220 Patch Part 1               "  F0 41 10 2B 11 10 05 00 00 00 0D 5E F7
"U220 Patch Part 2               "  F0 41 10 2B 11 10 05 10 00 00 0D 4E F7
"U220 Patch Part 3               "  F0 41 10 2B 11 10 05 20 00 00 0D 3E F7
"U220 Patch Part 4               "  F0 41 10 2B 11 10 05 30 00 00 0D 2E F7
"U220 Patch Part 5               "  F0 41 10 2B 11 10 05 40 00 00 0D 1E F7
"U220 Patch Part 6               "  F0 41 10 2B 11 10 05 50 00 00 0D 0E F7
"U220 Timbre [1]                 "  F0 41 10 2B 11 10 10 00 00 00 32 2E F7
"U220 Timbre [2]                 "  F0 41 10 2B 11 10 11 00 00 00 32 2D F7
"U220 Timbre [3]                 "  F0 41 10 2B 11 10 12 00 00 00 32 2C F7
"U220 Timbre [4]                 "  F0 41 10 2B 11 10 13 00 00 00 32 2B F7
"U220 Timbre [5]                 "  F0 41 10 2B 11 10 14 00 00 00 32 2A F7
"U220 Timbre [6]                 "  F0 41 10 2B 11 10 15 00 00 00 32 29 F7
"U220 Rhythm Setup Common        "  F0 41 10 2B 11 11 00 00 00 00 1A 55 F7
