Number: A1TH081390U307 Subject: ELS II v2.15 NCR PC-8 Machine Problem Date: September 13, 1990 - - - - - - - - - - - - - - - - - - - - - - - - - - - PROBLEM: A customer reported a problem running ELS-II v2.15 non-dedicated on a NCR PC 8 machine. They got the error "Problem with drive 00. Error reading disk redirection information. Error reading NetWare configuration information." when they tried to boot up ELS-II v2.15 non-dedicated on a NCR PC 8 machine. They tried the ISADISK kit for ELS, but they still got the same error. They tried three different controllers and two or three different drives. They even tried three different RAM boards. If they generated a dedicated server, everything worked fine. SOLUTION: They replaced the BIOS in the machine with the current Phoenix BIOS and it worked. (X) This information was verified verbally.