Number: A1TH083190U532 Subject: Slow Response After Upgrading NetWare or Adding Second Drive Date: January 23, 1991 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PROBLEM: Some customers, who upgrade from NetWare 286 v2.15a or below to v2.15c, find that their system runs extremely slow. When you look at FCONSOLE, everything looks great. There seems to be no reason for this to be running slow. It has also been reported to happen after adding a second drive. SOLUTION: ATDISK driver from NetWare 286 v2.12 or v2.15A seems to correct the performance problem. When upgrading they used the ISADISK driver, even the new ISADISK on NetWire had the same performance problem. COMMENTS: Take the ATDISK.DSK and copy it to the AUXGEN diskette (replacing ISADISK.DSK). Then copy the ATDISK.OBJ onto the disk labeled DSK_DRV_001. (X) This information was verified verbally