TECHNICAL BULLETIN Bulletin #1-269 Date: April 27, 1990 Error in 3Com Installation Supplement The addendum to the NetWare Installation Supplement for 3Com Etherlink and Etherlink Plus (revision 1.00, P/N 101-385-001) contains erroneous information. Specifically, the configuration option table (Figure 2) is incorrect for every option. The correct configuration option information for DOS is listed below. 3Com 3C503 EtherLink II 0. I/O = 300h, INT = 3, DMA = 1, BNC 1. I/O = 310h, INT = 2, DMA = 3, BNC 2. I/O = 330h, INT = 4, RAM = C8000, BNC 3. I/O = 350h, INT = 5, RAM = CC000, BNC 4. I/O = 250h, INT = 3, RAM = D8000, BNC 5. I/O = 280h, INT = 2, RAM = DC000, BNC 6. I/O = 2A0h, INT = 4, DMA = 1, BNC 7. I/O = 2E0h, INT = 5, DMA = 3, BNC 8. I/O = 300h, INT = 3, RAM = C8000, BNC 9. I/O = 310h, INT = 2, RAM = CC000, BNC 10. I/O = 330h, INT = 4, RAM = D8000, BNC 11. I/O = 350h, INT = 5, RAM = DC000, BNC 12. I/O = 250h, INT = 3, DMA = 1, BNC 13. I/O = 280h, INT = 2, DMA = 3, BNC 14. I/O = 2A0h, INT = 4, RAM = C8000, BNC 15. I/O = 2E0h, INT = 5, RAM = CC000, BNC 16. I/O = 300h, INT = 3, DMA = 1, DIX 17. I/O = 310h, INT = 2, DMA = 3, DIX 18. I/O = 330h, INT = 4, RAM = C8000, DIX 19. I/O = 350h, INT = 5, RAM = CC000, DIX 20. I/O = 250h, INT = 3, RAM = D8000, DIX 21. I/O = 280h, INT = 2, RAM = DC000, DIX 22. I/O = 2A0h, INT = 4, DMA = 1, DIX 23. I/O = 2E0h, INT = 5, DMA = 3, DIX 24. I/O = 300h, INT = 3, RAM = C8000, DIX 25. I/O = 310h, INT = 2, RAM = CC000, DIX 26. I/O = 330h, INT = 4, RAM = D8000, DIX 27. I/O = 350h, INT = 5, RAM = DC000, DIX 28. I/O = 250h, INT = 3, DMA = 1, DIX 29. I/O = 280h, INT = 2, DMA = 3, DIX 30. I/O = 2A0h, INT = 4, RAM = C8000, DIX 31. I/O = 2E0h, INT = 5, RAM = CC000, DIX Although the supplement is incorrect, the correct options are displayed when choosing the configuration in SHGEN under DOS. However, when the Multiple Link Interface Drivers (MLID) are installed as device drivers under OS/2, the configuration options are not displayed. The default configuration for OS/2 is: I/O = 300h, INT = 3, RAM = C8000, BNC Note that the Base Memory Address may not be set to "Disabled" when running the 3C503 board with the NetWare Requester for OS/2. See the NetWare Requester for OS/2 Supplement for additional information on reconfiguring the NetWare Requester.