ANGOSS SmartWare Plus README File 2.65b

This file contains corrections to the manuals and information on items
that have been changed since the manuals went to print.

The following topics are discussed:



WINDOWS

   *	Printing to Dot Matrix Printers
   *	Adjusting the Desktop in Windows95
	Microsoft 9.01 Mouse Driver
	Artisoft FAX Printer Driver
	ANGOSSW and MSWOAC Programs
	Multiple use of RAD Applications under Windows
	Windows For Workgroups
	Swap space in Windows
	Video Driver Issues
	High Characters Display
	SmartWare Window Size
	Unable to Open Base Font
	Communications Module on Windows 3.1

UNIX

	Alt-F5 on X11
	Printing in SCO

FUNCTIONS and COMMANDS

     *	CALL Function
     *	FILELIST Functions
	FOPEN Function
	FORMAT Function
     *	GET_FILE Function
     *	PROCESS_CREATE Function
	RAD Functions - Release Notes Corrections
		MODULE_CALL and MODULE_RETURN
		PASSWORD_CRYPT
		RUN_QUERY_STR
		Command Menu Interface (COMMANDLIST replacement)
	SUSPEND Command
	SCREEN SAVE Command


MISCELLANEOUS ITEMS

	IBM PS2 Problems
	Using SHARE
	LANtastic Network Driver
	Cross-platform Documents
	DDLs in RAD Programs
	SmartWare 1.51 Preference Files
	Documents with v1.51 Graphs
	Converting Older RAD Applications
     *	Activity Log in RAD Applications
	Font Map
	Metafiles for v2.65 DOS Users
	Fixed in this Version


 * Indicates new items





==============================================================================
				WINDOWS
==============================================================================

------------------------------------------------------------------------------
Printing to Dot Matrix Printers

Printing labels on some dot matrix printers under Windows, appears to switch
into NLQ mode, even though it was not asked to - slow printing.  Actually,
the real problem is that the default font (Standard 12pt Normal) is a filled
area font.  This is because the driver's default font cannot give us 10cpi
(12pt).  To resolve this, use the TOOLS PREFERENCES FONT-MAP NORMAL command
and specify the font that should be used when Standard 12pt is selected.
Make sure that the Source is Windows Font (the Source is shown at the bottom
of the font options editor).


------------------------------------------------------------------------------
Adjusting the Desktop in Windows95

If you're installing on a network, you may need to set up your client
machines with the ANGOSS programs.  If you're not familiar enough with
Windows95 to do this, here are some tips:

	To create a new Folder (Group):

		Click the right mouse button on Start
		Select Open
		Open the File menu in the Start Folder
		Select New
		Select Folder
		Type in the new Folder name

	To create a new Shortcut (Item):

		Open a Folder
		Open the File menu in the Folder
		Select New
		Select Shortcut
		Enter the full program name or use the Browse button
		Select the Next button
		Enter the Shortcut name
		Select the Finish button

	Properties:

		Click the right mouse button on a Shortcut (Item)
		Select Properties


------------------------------------------------------------------------------
Microsoft 9.01 Mouse Driver

Problems with WIN32S and Microsoft 9.01 Mouse Driver have been encountered.
If, after starting SmartWare, you receive the message "GROWSTUB caused a
General Protection Fault in module POINTER.DLL", this is probably the case.

Microsoft has created a patch for the 9.01 mouse driver.  This patch has been
placed on disk 6 of the ANGOSS SmartWare disk set.  To install the patch,
execute the self-extracting file, HD1061.EXE and follow the instructions laid
out in the resulting README.TXT file.


------------------------------------------------------------------------------
Artisoft FAX Printer Driver

The Artisoft FAX printer driver cannot be used as a print server with
SmartWare.


------------------------------------------------------------------------------
ANGOSSW and MSWOAC

The ANGOSSW and MSWOAC programs are identical.


------------------------------------------------------------------------------
Multiple use of RAD Applications under Windows

A single user running two copies of the same RAD App under Windows may produce
a "Sharing violation". You can continue anyway or, to avoid this problem, do
not use duplicate login IDs.


------------------------------------------------------------------------------
Windows For Workgroups

SmartWare will not run over a network in Windows For Workgroups version prior to
3.11. This problem (and others regarding opening too many files) is resolved by
upgrading to version 3.11.


------------------------------------------------------------------------------
Swap space in Windows

SmartWare may crash if Windows runs out of disk space for its swap file. If this
happens, free up disk space.  If possible, to ensure the space used for
swapping, use a permanent swap file (setting found in the Control Panel's
386 Enhanced icon).


------------------------------------------------------------------------------
Video Driver Issues under Windows

In general, there are a number of video problems that can be resolved by
either obtaining an updated video driver from your adapter's manufacturer,
or by switching to a standard VGA or SVGA driver.  The video driver setting
can be changed in Main's Windows Setup icon or by running the Windows setup
program from DOS.

Possible screen corruption with Orchid video driver with Win32 applications.
Obtain a driver with a version higher than 4.1.

Possible problem with the graphics accelerator, Promis S3 2.21. C805. Freecell
will not run either.  Use a standard VGA or SVGA drivers instead.


------------------------------------------------------------------------------
High Characters Display

SmartWare screen fonts in Windows are the same as the DOS WYSIWYG fonts. The
character set between 128 and 255 vary from the DOS character set, therefore, if you
are SCREEN PRINTing those characters, your display will be incorrect.  Using some
Windows FONTS, such as Terminal, match the DOS character set and will correct the
problem.  Ideally, you should use the SPSYMMAP() function to print box characters
since this will guarantee portability between DOS, Windows, character Unix and X11.


------------------------------------------------------------------------------
SmartWare Window Size

If SmartWare's window appears to wide, either increase the Windows screen resolution
(use a SVGA driver) or use a font that's less than 8 pixels wide (8*80 = 640).


------------------------------------------------------------------------------
Unable to Open Base Font

Some versions of Windows are unable to use the ANGOSS screen fonts. When this
occurs, the message "Error opening base font" occurs. To work around this problem,
go to the configure menu and turn Use ANGOSS Screen Fonts off. A good alternative is
to use the Terminal font.


------------------------------------------------------------------------------
Communications Module on Windows 3.1

Unfortunately, the WIN32S driver does not support 32 bit communications. As a
result, the Communications module is not available on Windows 3.1.




==============================================================================
				UNIX
==============================================================================

------------------------------------------------------------------------------
Alt-F5 on X11

The Alt-F5 key cannot be used for popup menus on X11. This because the window
manager is dealing with the key stroke and SmartWare never sees it.  Remap the
key in the .mwmrc file.


------------------------------------------------------------------------------
Printing in SCO

Problems may occur when printing large documents under SCO Unix. This is because
LPPR is in "cooked" mode.  Place LPPR in "raw" mode or use a dumb filter.




==============================================================================
			FUNCTIONS and COMMANDS
==============================================================================


------------------------------------------------------------------------------
CALL Function

The CALL function executes an SPL function:

     CALL

          Format: CALL( text, <,txt/num> <,txt/num> <,...> )
          OS: All
          Scope: All
          Returns: Conditional


          CALL executes an SPL public function.  This function's name
          is specified in the first parameter.  The remaining
          parameters are actually the parameters passed to the public
          function - note that these must match the number of
          parameters expected by that function.  Failure to do so will
          cause a run-time error.

            CALL( "FunctionName", "parameter1", ... )


          As an alternative, INDIRECT can be used to execute SPL
          public functions.  Additionally, INDIRECT executes SmartWare
          functions - CALL does not.  CALL's advantages, however, are:
          the "function call" is not built as a string and, pointers
          can be used in its parameters. Compare the follow lines of
          code:

            INDIRECT( "Msg(" & CHR(34)|"Hello World"|CHR(34) & ")" )


            CALL( "Msg", "Hello World" )

          If CALL fails, 0 is returned (e.g., an invalid number of
          parameters was passed).  Otherwise, output from the public
          function is returned.


          Example:

          This simple example requires two programs.  The first
          program, containing the public function, is loaded in
          memory.  The second program, when executed, calls the public
          function and passes it a string and a number.  Msg() then
          prints both values on the screen and returns "OK".

            '****** LOADED PROGRAM ******

            PUBLIC Msg()

            FUNCTION Msg( $string, #number )
                 MESSAGE $string & STR(#number)
                 RETURN "OK"
            END FUNCTION


            '****** CALLING PROGRAM *****

            MAIN
            LOCAL $return
                 $return = CALL( "Msg", "Hello World", 1234 )
                 MESSAGE "Msg return:" & $return
            END MAIN


------------------------------------------------------------------------------
FILELIST Functions

The following three functions are used to return file names:


     FILELIST_OPEN

          Format: FILELIST_OPEN( text, numeric )
          OS: ALL
          Returns: text

          This initiates a file list and returns the first file
          matching the file spec.

            FILELIST_OPEN( $filespec, #directories )

          The first parameter indicates the file spec.  Path and wild
          card characters can be included.  For example, when "*.txt"
          is passed, this function opens a file list on the current
          directory and filters out any file that does not have a
          "txt" extension.

          Directories are included in the file list when the second
          parameter is set to TRUE (1).

          If no files or directories are found, a null string ("") is
          returned.  Otherwise, the first matching file or directory
          name is returned.

          To get the next name, use FILELIST_NEXT.

          Except when a null string is returned (no files or
          directories found), the SPL program must eventually close
          the list with the FILELIST_CLOSE function.


          Example:

          The example code opens a file list and returns the first
          file matching the "*.txt" file spec in the current
          directory.  A WHILE loop is then started.  If no files or
          directories are found, the loop is aborted.  If a file is
          found, its name is displayed, a close flag is set, and the
          next file is returned.  This continues until FILELIST_NEXT
          returns a null string (no more files found).  Finally, if
          the close flag is set, FILELIST_CLOSE is called.


            MAIN
            LOCAL $file #close

                 $file = FILELIST_OPEN( "*.txt", 2 )
                 WHILE $file <> ""
                      MESSAGE $file
                      #close = 1
                      $file = FILELIST_NEXT
                 END WHILE

                 IF #close
                      FILELIST_CLOSE
                 END IF

            END MAIN


          Notes:

          Multiple file lists can be opened.  Because FILELIST_OPEN
          uses a stack, it can be called again before a FILELIST_CLOSE
          is issued.  This has the effect of leaving the previous list
          open and making the new list current - useful when climbing
          up and down directory structures.  When the new list is
          closed, the previous list becomes active and FILELIST_NEXT
          continues to operate where it left off.  The maximum number
          of open lists is 100.

          Lists must eventually be closed.  If repeatedly left open,
          errors will occur and SmartWare will not be able to find
          files.

          If FILELIST_OPEN does not return a file or directory name,
          FILELIST_CLOSE should not be called.  In this case, no list
          is actually opened and FILELIST_CLOSE may, inadvertently,
          close the current list.

          The file list functions do not employ a user interface.  Use
          FILEPROMPT for that task.


          See also FILELIST_NEXT and FILELIST_CLOSE.




     FILELIST_NEXT

          Format: FILELIST_NEXT
          OS: ALL
          Returns: text

          This returns the next file or directory name in an opened
          file list.  When FILELIST_NEXT returns a null string (""),
          no more files or directories exist in the list.

          For details on using file lists, refer to the FILELIST_OPEN
          function.




     FILELIST_CLOSE

          Format: FILELIST_CLOSE
          OS: ALL
          Returns: 0

          This closes an open file list.  For every successful call to
          FILELIST_OPEN, a close must be issued.  Failure to do so
          will cause errors and SmartWare will not be able to find
          files.

          For details on using file lists, refer to the FILELIST_OPEN
          function.


------------------------------------------------------------------------------
FOPEN Function

The FOPEN ro_mode works differently between DOS and Unix. In Unix, if you use
FOPEN to open a file in ro_mode, you must have write permissions since the file must
be locked.  In DOS you can open a file in ro_mode with just read permissions.


------------------------------------------------------------------------------
FORMAT Function

The function format(0.5,0) in the spreadsheet returns 0 whereas you may be expecting
1. This is NOT a bug.  SmartWare conforms to the IEEE Standard for binary Floating-
Point Arithmetic (IEE Std -754-1985) (Sections 4.1 and 5.5). "If the two nearest
representable values are equally near, the one with its least significant bit zero shall be
delivered."


------------------------------------------------------------------------------
GET_FILE Function

This is a RAD function used to load views.

     GET_FILE

          Format: get_file($pth,$vw,$typ,#cur,#excl,#retry,#hnd,#ind)
          Module: database
          Return: result string

          This RAD function loads the specified view or makes it
          current if the view is already loaded.  This last action
          assumes that the #cur parameter is set - see below.


          Parameters:

            $pth    The path of the view.  If its value is a null
                    string, the path is determined by the RAD
                    application's internal data (i.e., dv_info).

                    NOTE: If the view is already loaded, the path
                    parameter is ignored.  In cases where the
                    application uses multiple views with the same
                    name, it is safer to unload the view and call
                    GET_FILE again - see the Return Strings section
                    below.

                    If the path parameter is a view name prefixed with
                    a question mark (e.g., "?customer"), GET_FILE will
                    find that view's path (again in dv_info) and use
                    it.  Typically, this is done when loading a
                    standard-view that is normally attached to a
                    custom-view but does not share the same name.

            $vw     The view name.  Do not include the path or
                    extension.

            $typ    Indicates the type as custom-view or
                    standard-view.  Valid options for this parameter
                    are "vw" for custom-view and "vws" for
                    standard-view.

            #cur    Makes the view current.  Valid options for this
                    parameter are 1 (view is current) and 0 (view is
                    active).

            #excl   Loads the view as exclusive - this prevents other
                    users from loading the file.  Note that the #cur
                    parameter must be true (1).

                    NOTE: If the view is already loaded but is not
                    exclusive, unload it before calling GET_FILE
                    again, otherwise the view will not be reloaded -
                    see the Return Strings section below.

            #retry  Number of load attempts.  If this parameter is set
                    to 0, the program is interrupted and the user is
                    prompted to retry or abort the load attempt.  A
                    value greater than 0 indicates the number of
                    uninterrupted retries.  In this case, after each
                    failed load attempt, the function pauses before
                    retrying.  This pause is increased by one minute
                    per attempt (e.g., after the ninth attempt, the
                    function waits nine minutes before retrying).

            #hnd    Message file handle.  When this parameter is
                    greater than 1, messages are written to the opened
                    file represented by the handle.  The program will
                    not be interrupted when errors occur.  Typically,
                    this is used in an AUDITED PROGRAM where the
                    standard handle passed to GET_FILE is ##mhnd.
                    Messages are then written to the Batch Update/
                    Process Log.  When the handle is set to 0, error
                    messages are displayed on the screen while the
                    program waits for user input.

            #ind    Indentation level for messages.


          Return Strings:

            "error"           Unable to load the view.

            "loaded"          GET_FILE loaded the view.

            "already loaded"  View was previously loaded.


          Example 1:

          The code fragment below loads the view, if it is not already
          loaded, and makes it current.  Exclusive mode is not
          invoked, load retries are prompted, and error messages are
          displayed on the screen.  For a more advanced usage, refer
          to the second example.

            FUNCTION Init()
            LOCAL $view

                 $view = "customer"

                 IF get_file("",$view,"vw",1,0,0,0,0) == "error"
                      RETURN 0
                 END IF

                 ... other initiation code

                 RETURN 1
            END FUNCTION


          Example 2:

          The code fragment below was extracted from an AUDITED
          PROGRAM.  It loads the inventory custom-view exclusively.
          In case of loading errors, six attempts will be made to
          retry the load.

          Note that, because the view must be loaded exclusively, an
          unload is performed if GET_FILE returns "already loaded".
          The WHILE loop then causes a reload.

            FUNCTION UpdateInventory()
            LOCAL $view $result

                 $view = "inventry"

                 WHILE TRUE
                      $result = get_file("",$view,"vw",1,1,6,##mhnd,2)
                      IF $result == "already loaded"
                           FILE UNLOAD VIEW $view|".vw"
                      ELSE
                           EXIT WHILE
                      END IF
                 END WHILE

                 IF $result == "error"
                      rec_message( "Could not load" & $view )
                      rec_message( "* Critical view - Batch aborted" )
                      RETURN 0
                 END IF

                 ... code to update view

                 RETURN 1

            END FUNCTION


          Notes:

          While GET_FILE can be used to load views in any program, it
          has a number of features that make it valuable in Batch
          Processing programs where the program runs unattended.  The
          message and load retry facilities are ideal in that, no
          program interruption is required.  Further, the exclusive
          loading mode eliminates potential LOCK RECORD problems and
          other update record issues.


------------------------------------------------------------------------------
PROCESS_CREATE Function

This function no longer duplicates the program name in the second
parameter.  The Paintbrush example in the manual, now looks like:

	PROCESS_CREATE( "c:\windows\pbrush", "c:\windows\cars.bmp" )

If the function is successful, PROCESS_CREATE will return a process
number otherwise, -1 is returned.  For 16 bit applications in Win32S,
0 indicates a successful return.  Note that, under Unix, a process number
will probably be returned regardless of success.


------------------------------------------------------------------------------
RAD Functions - Release Notes Corrections

The Release Notes indicate that the deleted function EDIT_FIELDS
can be found in $$advr|"edfld" if required.  It is actually found in
$$advr|"oldlib".  As well, the function COMMANDLIST cannot be found
in $$advr|"oldlib" but is, in fact, still maintained in the RAD
shell.  However, COMMANDLIST is no longer recommended - its replacement,
the CMENU_ functions are discussed in this section under the title
Command Menu Interface.  The CMENU_ functions are actually an
interface to the GETCOM function that is listed in the Release Notes.
The remaining new functions listed in the Release Notes (MODULE_CALL,
PASSWORD_CRYPT, and RUN_QUERY_STR) are also discussed in this
section.


MODULE_CALL()
MODULE_RETURN()

     These two functions are used to call a project in another
     SmartWare module when running a RAD application.  They do
     all the work necessary to save and restore the current
     application position.

     The syntax for MODULE_CALL is:

     MODULE_CALL(#module,$project_file)

     The parameters are:

     #module        - 1=SS, 2=WP, 3=DB, 4=CM, (-1=special)
     $project       - text string which is path and filename to
                    execute when at the destination module
                    (required)

     If #module = -1 then the caller is to do the actual module
     change.  (e.g., using the send command.)  If -1 is used, the
     caller must execute the project $$advr|"ppmodch.rf3", which
     in turn executes the project specified by $project_file.

     Return values are:

          0 = Fail
          1 = If #module=-1 and successful.
          Doesn't return if 1<=#module<=4 and successful

     MODULE_RETURN()

     The MODULE_RETURN() function is only used after
     MODULE_CALL().  It requires no parameters.  When called, it
     returns to running the application at the point that
     MODULE_CALL() was issued.




PASSWORD_CRYPT($pass_word)

     This function is just like password() except the $pass_word
     parameter is a string encrypted with the CRYPT() function.




RUN_QUERY_STR($name,$query,#mess_hnd)

     This function runs a query specified by the $query string
     variable.  It avoids the need for separate query files and
     makes code more readable by embedding query statements in
     project file.

     The parameters are:

     $name          -file name of index that is generated (do not
                    supply path or extension) path will be
                    $$workdir, ext=.idx

     $query         -a string containing the logical expression
                    of query
                    Use \n for new line
                    Use \' for double quotes (see example)

     #mess_hnd      -file handle of an already open text file for
                    messages
                    -0 if none
                    -if >0 query name and expression is written
                    when executed for tracing purposes

     Return values:

          -if successful, the number of records selected
          -if error occured, 0 means error was caused internally
          by the RUN_QUERY_STR() function, otherwise a negative
          value indicates a SmartWare error number (multiply this
          by -1 to get real number).

     Examples:

          run_query("dept","[Department]=\'A\'",0)

          $dept = "A"
          run_query("dept","[Department=\'"|$dept|"\'",0)


Command Menu Interface (COMMANDLIST replacement)

     A series of SPL functions have been written to simplify the
     interface to the pulldown menus and as an improved
     alternative to the old commandlist() function.  These
     functions allow developers to quickly specify and run a
     pulldown menus or command lists.

     Note: If you are not using these commands from within RAD,
     you must load the RAD libraries by executing the following
     line before using these functions:

     execute path(systpath)|"loadalib.rf0" in-memory

     Constructing a menu.

     The functions dicussed here allow you to quickly build a
     menu.  In essence, they are a simplified alternative to the
     mnu_open() and mnu_insch() functions.  Note that these
     functions are written in SPL and, in fact, use the mnu_
     functions.

     cmenu_init()

     This function starts a new menu.  It returns 0 for fail, 1
     for success.

     cmenu_add($desc,$act,$linehelp,$helpfile)

     Adds an item to menu being built.  The following parameters
     are used.

     $desc          -Command description.  Use -> to specify
                    levels.  For example "File->Exit" creates a
                    command named exit under a submenu named
                    file.
     $act           -Command action.  A string that can be used
                    to identify the choice.  If left blank then
                    the description of the choice is returned.
     $linehelp      -The autohelp line for the current choice
     $helpfile      -The base file name of the file containing
                    help text for this command.

     cmenu_makemnu()

     This function builds a menu (using mnu_info() related
     functions) based on the information previously provided with
     cmenu_add().

     It returns a menu handle or 0 if a failure occurred.

     cmenu_free(#menu)

     Frees the memory used by a menu file.  (It is the same as
     mnu_free().


     Running a menu

     The cmenu_run() function displays a menu and responds to the
     end user.  The menu can be built with the above listed cmenu
     functions or with the mnu_info() related functions.  For a
     "quick and dirty" menu, the menu choices can also be passed
     as a text string.  Here is the format of cmenu_run()

     cmenu_run(#menu,#nav,$key_cb,$com_cb,$h_pth,$h_ext,$#data)

     The parameters are:

     #menu          -The menu handle or a space seperated text
                    string listing commands.
     #nav           -Navigation keys.  If it is set to 1, then
                    the end user may use the mouse or keystrokes
                    to move around the database, spreadsheet or
                    document. Otherwise, use 0.
     $key_cb        -Keystroke call back function.  If you want
                    your own function to respond to mouse events,
                    keystrokes, etc. then list the name of the
                    public function to deal with these events.
                    See below for more details.  If you do not
                    want to use it, simply enter "".
     $com_cb        -Command call back function.  It is best if
                    you specify a function that will be called
                    when a command is selected.  This way, the
                    processing overhead to set up the menu only
                    need be run when the menu is entered.  See
                    below for details.  If you do not specify
                    this parameter (i.e., enter ""), then
                    cmenu_run() will terminate when the user
                    selects a choice, returning the action (or
                    description) of the choice selected.
     $h_pth         -Help path.  This must be a directory name
                    which contains help files for the menu.
     $h_ext         -Help file extension.  This is the three
                    character file extension that the help files
                    for this menu will have.  When a user
                    requests a help file the path ($h_pth), file
                    name (from cmenu_add()) and the extension
                    ($h_ext) are combined to calculate the file
                    to display.
     $#data         -This parameter is passed to the call back
                    functions.  You may use it however you want.
                    If more than one data element is required,
                    consider using an array pointer.

     If you are running in character mode, (##pulldowns=0) then a
     command list will be used.  A command list is a ring style
     menu occupying the bottom portion of the text window.  If
     you are running in graphics mode, (##pulldowns=1), then
     pulldown menus, which sit above the text window, are used.


     Command Call Back Function

     The command call back function, which is passed as an
     arguement to cmenu_run(), is called when the end user
     selects a command.  You must write this function yourself.
     It must be a public function and it must have the following
     arguements:

     function my_callback($act,$#data,#menu,#choice)

     $act           -This is the "action" of the menu choice
                    selected as specified by the cmenu_add() or
                    MNU_ACT.  Typically, your function will
                    branch based on this value.
     $#data         -This is whatever was passed to cmenu_run().
     #menu
     #choice        -The #menu and #choice parameters are usually
                    not used.  They can be used to further
                    enquire about the menu choice selected.  For
                    instance the password, help file, object,
                    etc. can be obtained by passing these choices
                    to mnu_info().

     The command call back function should usually return 0.  If
     it returns a value other than 0, cmenu_run() will terminate,
     returning the same value that you returned.  So, when the
     user selects a choice that should terminate the menu, return
     a value other than 0.

     Key Call Back Function

     When a key call back function is specified in cmenu_run(),
     each time the user presses a key or uses the mouse this
     function is called.  As usual, the call back function must
     be public.  The key call back function requires this format:

     function my_callback(#key,$#data,#menu)

     #key           -Is the event id as returned by the EVENTINFO
                    function.
     $#data         -This is whatever was passed to cmenu_run().
     #menu          -The #menu and #choice parameters are usually
                    not used but can be used by mnu_info() to
                    obtain more information about the current
                    menu.

     The key call back function must return 0 if the event was
     not handled, 1 if the event was handled and 2 if you want
     the menu to terminate.

     Examples

     Each program usinf the cmenu functions must include the
     following declarations:

     ' Menu Building
     external cmenu_init()
     external cmenu_add()
     external cmenu_makemnu()
     external cmenu_free()

     ' Menu Run
     external cmenu_run()

     global simple()
     global very_simple()
     global still_simple()
     global complex()


     ' If you are not using RAD, the functions must be loaded by:

     execute path(syspath)|"loadalib.rf0" in-memory


     ' VERY SIMPLE EXAMPLE

     function very_simple()
     local $ret

          $ret =  cmenu_run("Run Exit Copy Delete", 0, "","","","","")
          ' Call a command menu with above commands, no data base navigation

          case $ret
           when "Run"
            message $ret
           when "Exit"
            message $ret
           when "Copy"
            message $ret
           when "Delete"
            message $ret
           otherwise
            message "huh:"|str($ret)
          end case

     end function


     ' SIMPLE EXAMPLE

     function simple()
     local $ret #menu
     ' Simple Example

          ' Build a Menu
          if cmenu_init()
           cmenu_add("Run","r","","")
           cmenu_add("Exit","x","","")
           cmenu_add("Copy","c","","")
           cmenu_add("Delete","d","","")

           #menu = cmenu_makemnu()

           $ret = cmenu_run(#menu, 1, "","","","","")
           ' Call command menu, with buildmenu with navigation

           cmenu_free(#menu)

           case lower($ret)
            when "r"
             message $ret
            when "x"
             message $ret
            when "c"
             message $ret
            when "d"
             message $ret
            otherwise
             message "huh:"|str($ret)
           end case
          end if
     end function

     ' AN ADVANCED EXAMPLE

     public my_commands()
     public $mydir

     function still_simple()
     local #menu $ret
          $mydir = ""
          if cmenu_init()
           cmenu_add("File->Run","run","run a program","run")
           cmenu_add("File->Exit","x","quit this program","quit")
           cmenu_add("File->Whatever","what","quit this program","quit")
           cmenu_add("Edit->Copy","cpy","copy something","cpy")
           cmenu_add("Edit->Delete","del","delete something","del")

           #menu = cmenu_makemnu()

           $ret = cmenu_run(#menu,1,"","my_commands",$mydir,"txt","")

           cmenu_free(#menu)

          end if
     end function

     ' 0=continue, anything else exit
     function my_commands($action,$data,#menu,#choice)
          case $action
           when "run"
            message $action
           when "cpy"
            message $action
           when "x"
            message $action
            return 1 ' This terminates menu
           when "del"
            message $action
           when "what"
            message $action
           otherwise
            message "action:"|$action
          end case
          return 0
     end function

     ' COMPLEX EXAMPLE

     public my_keys()
     ' Also uses my_commands from previous example

     function complex()
     local #menu $ret
          $mydir = ""
          if cmenu_init()
           cmenu_add("File->Run","run","run a program","run")
           cmenu_add("File->Exit","x","quit this program","quit")
           cmenu_add("Edit->Copy","cpy","copy something","cpy")
           cmenu_add("Edit->Delete","del","delete something","del")
           cmenu_add("File->Whatever","what","quit this program","quit")
           cmenu_add("Data->Find->Name","f name","find name","fn")
           cmenu_add("Data->Find->Phone","f phone","find phone","fp")
           cmenu_add("Data->Order->Name","o phone","order name","on")
           cmenu_add("Data->Order->Phone","o phone","order phone","op")

           #menu = cmenu_makemnu()

           $ret = cmenu_run(#menu,1,"my_keys","my_commands",$mydir,"txt","Hi There")

           cmenu_free(#menu)

          end if
     end function

     function my_keys(#key,$data,#mnu)
          case #key
           when {Alt-H}
            message $data
            return 1 ' Thank you, I have dealt with event
           when {Alt-Q}
            message "bye alt-q"
            return 2 ' Let's get out of menu
           when {f10}
            message "bye f10"
            return 2 ' Let's get out of menu
           when {esc}
            message "bye esc"
            return 2 ' Let's get out of menu
          end case
          return 0 ' I don't know about this event
     end function


------------------------------------------------------------------------------
SUSPEND Command

The SUSPEND command always paints command lists regardless if repaint is off. Use
SUSPEND ENTRY, KEYS ALT-Z instead.


------------------------------------------------------------------------------
SCREEN SAVE Command

SCREEN SAVE stores a portion of the screen in memory.  The bytes size for
characters differ: DOS character = 2 bytes, DOS WYSIWYG = 3 bytes, Unix= 4
bytes).  Add approximately 10 bytes for header (varies by system). Use SCR_TEXT
instead.

Note that buffer variables created with SCREEN SAVE are not compatible across
platforms. For example, if you write this variable to disk from DOS and read it in
under Unix, SmartWare may terminate.




==============================================================================
			MISCELLANEOUS ITEMS
==============================================================================


------------------------------------------------------------------------------
IBM PS2 Problems

An "Unexpected interrupt in 000A in OAC.EXE at 0246:0118" error occurs running
angoss.exe (16 bit version) on an IBM PS2 model 30 (286) with 2MB RAM.


------------------------------------------------------------------------------
Using SHARE

When using SHARE, use /L: /F: to specify the number of locks and file space (in
bytes) for MS DOS. For example:

	SHARE /L:100 /F:10240

gives 100 records and 10240 bytes for path and file names of share files.


------------------------------------------------------------------------------
LANtastic Network Driver

For LANTastic networks, use DOS SmartWare's network driver, NET_N46.


------------------------------------------------------------------------------
Cross-platform Documents

Document colors may differ across OS platforms. Use the WINDOW Paint command
to change this.


------------------------------------------------------------------------------
DDLs in RAD Programs

There is a new way to specify a DDL in a program.

Function:  ddl_str($type,$pathexp,$lookexp,$destfld,$addcond)

You may need to look at the original .ddl file (which may have been deleted) to figure
out the values.  If there are quotation marks in the data use chr(34) to embed them. The
parameters are:

	$type	 = "1" simple, "2" binary query, "3" file per record
	$pathexp = FPR only, path of dest .vw
	$lookexp = expresion evaluated on source
	$destfld = key field in dest (no brackets)
	$add	 = expression evaluated on destination

If you had used $$fct to set the .ddl file, then use:

	$$fct=ddl_str("1","","[fld]=a","fld","not(deleted)")

If you use loaddataview(), use "ddl"|ddl_str(....) as the ddl parameter.


------------------------------------------------------------------------------
SmartWare 1.51 Preference Files

There are differences between SmartWare version 1.51 and 2.65 preference (def) files.
If you run with 1.51 preference files, Tools Preferences Hardware shows you the
original options, but is followed by a FATAL ERROR 316 message on exit. Use
current preference files instead.


------------------------------------------------------------------------------
Loading Documents with Graphs Created in v1.51

We have discovered a minor incompatibility between v1.51 and subsequent versions.
The space within the document allocated for a graph was inadvertantly changed,
leading to unpredictable results when documents with graphs are transferred.
Unfortunately there is no way to automatically convert. If you want to move a 1.51
document with graphics to a later version (or vice versa), load the document with the
version that created it (i.e.,1.51), remove the graphics, and save. Load the document
into the target version (i.e.,2.65) and re insert the graphs.


------------------------------------------------------------------------------
Converting RAD 2.5x and 2.61 Applications

In addition to the changes made to the underlying structure of RAD menus
(discussed in the Release Notes), the RAD App start up procedure has been
simplified.  Developers should be aware of the following changes:

ANGOSS.CFG File

     The $$adev and $$syspath variables, when set in the
     angoss.cfg file, should only be used as override mechanisms.
     As a result, these variables should be removed from the CFG
     file if that file was created prior to version 2.65.


DOS Start Up Batch File

     Due to the new RAD startup parameter for SmartWare, this
     file has a simplified structure. While your original batch
     file should work, you may need to remove the reference to
     the ANGIIDVR variable.

     You may want to consider replacing the file altogether. One
     way to do this is to create a temporary system with Makenew
     (make sure to create a DOS script), save the original batch
     file and replace it with the one just created. You will then
     need to edit the new file by changing the temporary system's
     path references -- there should be two of them -- to the
     original system's path.  For example the following line
     fragments:

          if not exist C:\TMP\system\users\
          angossx -RADC:\TMP -omC:\ANGOSS\

     would become,

          if not exist C:\ORGSYS\system\users\
          angossx -RADC:\ORGSYS -omC:\ANGOSS\



START.PF3 and LOGIN.PF3

     If you have customized these files, you should replace them
     with the corresponding PF3 files found in the
     ANGOSS\APSYS\DEV directory. You must then manually add your
     previous customization work and re-compile them.

Menu Modes

     Menu mode 6 defaults to using the graphical menu mode.  If this is not
     possible, the application automatically switches to mode 3.

     To change to this new mode, edit the ANGOSS.CFG file in the home
     directory of the system and change the line that begins with
     ##mmod to specify mode 6.

	##mmod		Menu display mode		N	6


------------------------------------------------------------------------------
Activity Log in RAD Applications

Applications generated in RAD versions prior to v265b, created an activity
log where the date field was a number.  If you import with this scenerio,
the date field is lost - use the Developer to change the field type from a
number to a date field type.


------------------------------------------------------------------------------
Font Map

TOOLS PREFERENCES FONT-MAP

This maps the Standard font options (normal, condensed, compressed,
and expanded) to specified fonts.  Remapping the Standard font
options allows you to specify the same sized fonts across different
printers and platforms.  For example, if a table report uses the
Standard font with the compressed option, the report may work fine on
one printer but not on another.  To solve this problem, remap the
compressed option for that printer.

Application programmers should note that, to ensure portability of
applications, use only the Standard font in printable objects such as
reports.

Font-Map information is stored in the fontmap.def file.  A record is
entered for each printer that contains a font mapping.  This means
that you must first select the printer before mapping one or all
of the Standard font options.  If required, repeat this step for
each printer on your system.

Note that this command can also be issued through SPL. In this case
the keyword SET followed by the font string must be added. For
instance, to set the Standard font's expanded option to 14 point
Courier, the command might look like this:

	TOOLS PREFERENCES FONT-MAP EXPANDED SET "Courier 14Pt."


------------------------------------------------------------------------------
Metafiles for v2.65 DOS Users

If you are installing the patch to the DOS version of SmartWare 2.65, the
four previously missing metafiles will be stored in your ANGOSS\
RESOURCE\MISC directory.  You can add these metafiles with the Tools
Resource Modify System (or Local) set of commands in the Main Module.
The metafiles fall into the miscellaneous catagory.


------------------------------------------------------------------------------
Fixed in this Version

Ref# Description
---- ------------------------------------------------------------------
1576 WYSIWYG text driver, help text display is italics.
2438 Sometimes crashes during a move in the custom-view editor.
2652 8 lines per inch printing in draft in SS module.
2661 Documentation generator always selects all choices.
2670 Screen painting and general performance with second instance in
     Win95 & NT is very slow.
2709 Due to a bug in the MicroSoft Windows math libraries, a number
     to the power of 0, returns 0 but s/b 1 - PC's with no coprocessor.
2710 Print current record only, prints wrong record - PC's with no
     coprocessor.
2736 Docgen produces "Invalid index to array" when there is more than one
     language.
2749 ROUND(0,0) shows 0.00e+000.
2767 Tools Zap asks whether you want to zap a file, even though "no" was
     selected on the initial screen.
2771 Problems printing with latest 550c driver
2772 Modify Document Information sometimes causes an error.
2781 GRAPHICS BMPLIB READ confuses file names.
2782 The graphics menu (menu6) sometimes displays the wrong icon.
2783 Insert Procedure/Job Stream appears twice.
2817 REALPTR under Windows gives error "Command not valid in Unix" - s/b
     "Command only valid in DOS".
2824 Most Help buttons on Insert Dialogs are broken.
2844 Minor problems with makenew.
2845 All Tools, "File-FIx, Krunch etc." commands in "File Structure
     Maintenace" have a bug which causes all db's to be selected.
2855 Ruler is inaccurate in Windows.
2859 Printing to disk goes to the printer.
2890 CA (Change Application) does not work.
2895 Using ##mmod=6 and ##pulldowns=0 causes double autohelp when a
     dataview is selected.
2904 ARRAYFIND and ARRAYSORT comsume memory.
2907 Substituion of DB in Edit Links complains that files do not
     match when they do.
2912 12x24 Font the underscore (_) shows as a blank.
2933 Table on Info Set view shows up as black on black in update mode.
2935 Toolbar does not show when ##mmod=6 and ##pulldowns = 0.
2940 DDE server not accepting multiple requests.
2992 Insufficient Memory printing from SS in DOS & Unix.
2997 Rounding with FORMAT errors.
3029 The color of the cursor of a table was black on black instead of
     default.
3061 Problems running and executing RAD reports.
3106 Could not move a block using pulldown menus.
3108 Pulldowns: The Layout jsutify center command caused an "Invalid
     action" message.
3109 Layout Lines Edit caused invalid action.
3110 Send (using command list menus) from WP or SS caused errors.
3114 Install program under Win95 asks to install Win32s.
3122 Glitches with file prompter on Windows 95.
3133 LGraphic, DingBat, fonts do not show under Windows (SS & WP).
3137 Invalid Row/Col Coordinates error occurs in RAD reports.
3138 Report object that does not exist in rp_exec() call gives misleading
     message.
3153 Spacing differences between DRAFT & ENHANCED printing.
3154 PROCESS_CREATE doesn't work with 16bit applications under NT & Win95.
3174 Filled Area Fonts in header or report are printed incorrectly.
3194 Problems occurred with a large number of menus in a RAD App - adding
     user modes, converting, changing colors.
3195 Various problems printing lines and shading.
3209 PFB (Project file beautifier caused - out of file handles) on some
     networked configurations.
3210 Problems occurred inserting/modifying graphs into a RAD
     application (SS).
3211 Displaying graphics from RAD app (SS) left stuff at bottom of screen.
3212 If a library was bound to an SS menu, which was called
     directly the DB, an error loading library occuured.
3213 A couple of minor bugs were fixed in Lint.