      STACKER NOTE                                         STACKER NOTE
                             OPTIMIZER ERROR 177
                  (Applies to Stacker 4.0 for Window & DOS)
      STAC FAX  4612 (11-01-1994)
      -----------------------------------------------------------------
                                      
      BACKGROUND
      
      Optimizer error 177 indicates that the Optimizer has found an
      earlier version of the Stacker device driver than it expects.
      This may occur if you update your Stacker files using S4UP.EXE,
      then later run REDBL from your original Stacker disk. S4UP.EXE
      provides the Stacker update file SUPDATE.EXE. This file updates a
      number of Stacker files on your system, including the Optimizer
      and the Stacker driver. If you later run the REDBL program from
      Stacker disk # 1, it replaces the Stacker driver on the hard
      drive with the version that is on the floppy disk. The Optimizer
      detects the older driver and refuses to run.
      
      SOLUTION
      
       Restore the new Stacker driver and rerun the Optimizer.
      
       1.  Change to the STACKER directory.
       2.  Locate the file SUPDATE.EXE. Ensure that it is still
           present. If not, copy it from wherever you have stored it to
           the STACKER directory. If you have deleted the file, run
           S4UP.EXE again from the STACKER directory.
       3.  Run SUPDATE.EXE from the STACKER directory. This will update
           the Stacker driver.
       4.  Restart the system for the update to take effect. You may
           now run the Optimizer.
      
      -----------------------------------------------------------------
      Copyright 1994 Stac Electronics