      STACKER NOTE                                         STACKER NOTE
                  UNCOMPRESS FAILS WITH OPTIMIZER ERROR 101
                          (Applies to Stacker 4.0)
      STAC FAX  4605 (12/94)
      -----------------------------------------------------------------
                                      
      BACKGROUND
      
      UNCOMPRESS must run the Stacker Optimizer before uncompressing
      your drive. If you receive error 101 while optimizing your
      Stacker drive, your system does not have enough memory to run the
      SDEFRAG utility. Although the Optimizer uses XMS memory, if
      available, it still requires some minimal amount of conventional
      DOS memory (the first 640K) to run. You must increase the
      conventional memory available on your system, and/or reduce
      SDEFRAG's memory requirements.
      
      SOLUTION
      
         - Ensure you are using the current Stacker Optimizer.
         - Increase conventional memory available.
         - Reduce SDEFRAG's memory requirements.
         - Run UNCOMP immediately after Optimization.
           
      Ensure you are using the current Stacker Optimizer
      
       1.  Go to a DOS prompt and change to the STACKER directory. Type
           DIR SDEFRAG2.EXE  <enter>. If the file is 9-06-94 or later,
           you have the current Optimizer. If the file date is earlier,
           update the Optimizer. Download the file S4UP.EXE from
           CompuServ, America On-Line, or the Stac BBS at (619) 431-
           5956. See the brochure "How to Contact Stac" for information
           on these services. If you do not have access to a modem,
           contact Stac Product Support Services for assistance.
       2.  After you obtain the update through on-line services, place
           the file in your STACKER directory and run it. The Optimizer
           will be updated automatically after you restart your system.
       3.  After the Optimizer is updated, run it again. You will
           probably not see the error again. If you do, proceed to the
           next section.
           
      Increase conventional memory available
      
      There are two methods of increasing your conventional memory,
      automatic or manual. Third party memory managers such as QEMM,
      386MAX, NETROOM, or MS-DOS's MEMMAKER are examples of programs
      which will automate the memory management process. Running a
      program such as these often will increase available conventional
      memory to the point where the Optimizer will run successfully. If
      an automated memory manager is not available, or it does not
      provide sufficient conventional memory, you may try using a
      simple memory configuration by manually editing your CONFIG.SYS
      file. This procedure will require DOS 5 or above. Note that if
      you have DOS 6 or above, you may press the F8 key when you get
      the message "Starting MS-DOS." This will allow you to select
      which lines of the CONFIG.SYS to run.
       
       1.  From the STACKER directory DOS prompt, type ED /C <enter>
       2.  Remark out (make inactive) every line in your CONFIG.SYS by
           typing REM <space> at the beginning of each line, except for
           the following lines:
           DOS=HIGH,UMB
           DEVICE=C:\<DIR>\HIMEM.SYS
           DEVICE=C:\<DIR>\EMM386.EXE <NOEMS or RAM>
           Where <DIR> is DOS or WINDOWS
           (Note: For Dos 6 or greater use the DPMS and STACHIGH lines
           below)
           DEVICE=C:\STACKER\DPMS.EXE
           DEVICEHIGH=C:\STACKER\STACHIGH.SYS
           (Note: For other versions of DOS use the Stacker lines that
           will appear something like these)
           DEVICEHIGH=C:\STACKER\STACKER.COM
           DEVICE=C:\STACKER\SSWAP.COM (this line may not appear)
       4.  Save the file and restart the computer.
       5.  Run the Stacker Optimizer from the DOS prompt. Go to the
           STACKER directory and type: SDEFRAG  /H drive: <enter> where
           drive: is the drive you wish to uncompress. Note: If SDEFRAG
           reports that the drive has very little fragmentation and
           recommends exiting, choose "continue" anyway.
       6.  If SDEFRAG runs successfully, IMMEDIATELY run UNCOMP. Type:
           UNCOMP drive: <enter>.
           
      Reduce SDEFRAG's memory requirements
      
      If the procedures above still do not allow the Optimizer to run,
      you may lower its memory requirements. You may run SDEFRAG with a
      special option. This option affects speed, but allows it to run
      in less memory. From the DOS prompt, type:
      
            SDEFRAG /buffer=# /F /H <enter>
      where # is a value between 256 and 4096, inclusive. By default,
      SDEFRAG normally runs at /buffer=4096. Smaller numbers use less
      memory. If you have XMS memory available, try using /buffer=1152
      first.
      
      Run UNCOMP immediately after Optimization
      
      IMMEDIATELY after successfully running the Optimizer, run UNCOMP.
      Do not restart your system, copy files to the disk, or do any
      other disk activity. From the DOS prompt type:
      
           UNCOMP drive: <enter>
      where drive: is the Stacker drive you wish to uncompress.
      -----------------------------------------------------------------
      Copyright 1994 Stac Electronics