      STACKER NOTE                                         STACKER NOTE
                              NOVELL DOS CHKDSK
                          (Applies to Stacker 4.0)
      STAC FAX  4305 (06-03-1994)
      -----------------------------------------------------------------
                                      
      BACKGROUND
      
      If you attempt to run the Novell DOS 7 version of CHKDSK, you
      will receive the error message "You have attempted to run a ver
      3.00 CHKDSK with a ver 4.00 Stacker Device....". While CHKDSK may
      continue to run, space reporting will be innacurate, and disk
      errors may not be repaired. To address this issue, Novell has
      distributed an updated version of its CHKDSK.
      
      SOLUTION
      
      Download the file D70U04.EXE from the Novell Bulletin Board at
      (408) 649-3696. This is a self-extracting ZIP file. When run, it
      will produce a new CHKDSK.EXE file and a text file, along with
      some other Novell DOS file updates. Read the text file in any
      editor and follow the directions you find there. The syntax when
      running the updated CHKDSK is:
      
      CHKDSK /NS <enter>
      
      Remember, if you want CHKDSK to make repairs to the drive, you
      still must use the /F parameter. For example:
      
      CHKDSK /NS /F <enter>
      
      Note that Novell periodically updates its maintenance file,
      D70U0n.EXE. As of this writing, the latest file is D70U04.EXE. In
      order to ensure you have the latest maintenance file, check for
      any later version on the Novell BBS. Contact Novell Product
      support for further details.
      -----------------------------------------------------------------
      Copyright 1994 Stac Electronics