UNIDEN 5000 and 6000 GTS Portable NAM Type: EEPROM Manufacturer: UNIDEN Programmer: Program or Service Handset with CP 505 Adaptor ESN Prefix DEC: 172 HEX: AC ESN, S/N Match Required: Yes Stamped Model Number: 5000 or 6000 GTS Number of Channels: 832 Programming Sequence: Power Off Remove Battery and install CP505 or CP505A adaptor Connect CP505(A) to power supply or to CP 504 battery eliminator per adaptor instructions Connect Program Handset to CP 505(A) adaptor White Handset (CP-010): Turn Power Switch On while holding * and # continue holding * and # for two seconds Blue Handset(CP-210): Turn Power Switch On Press SELECT + 2 + SEND Both Handsets: Enter step number, then data for individual parameter Press STO to enter data for each step Increment by pressing next step number To review parameters press: RCL + Step number + STO (to exit) To select Alternate NAM, Press 1 + STO + 90 (NAM 1) or 2 + STO + 90 (NAM 2) Press SEND to write NAM information PASS will appear in display if data is valid Step # of Digits 0 System ID: 5 XXXXX + STO 1 Local Use: 1 (0 or 1) + STO 2 MIN Opt: 1 (0 or 1) + STO 3 Mobile Number: 10 XXX-XXX-XXXX + STO 4 Initial Page Channel: 3 (333 or 334) + STO 5 Access Overload: 2 XX + STO 6 Preferred System: 1 [0 (B) or 1 (A)] + STO 7 Group ID: 2 XX + STO 8 Lock code (1): 4 XXXX + STO 9 Options F5 DTMF Duration: 1 0 - Continuous 1 - 100 ms Press STO to program phone New Unlock Code: RCL + 70 + Current 4 digit Unlock code + new 4 digit Unlock code System Select: X + STO + 8 + 8 X=1 A only X=2 B Only X=3 Home X=4 Standard AB or BA X=5 Inverted BA or AB