ALPINE 9510

                  NAM Type:  Fujitsu
              Manufacturer:  Fujitsu
                Programmer:  Curtis or Bytek
            ESN Prefix DEC:  150
                       HEX:  96
   ESN, S/N Match Required:  YES
      Programmable Handset:  No
        Available Channels:  666

       Phone Number Format:  XXX-XXX-XXXX
          Lock Code Format:  XXX

                MIN Option:  Enabled
          Repertory Option:  Enabled
          Handsfree Option:  Enabled or Disabled
          Local Use Option:  Enabled
     End-to-End Signalling:  Enabled
         Horn Alert Option:  Enabled
          System ID Format:  XXXXX
         Preferred Systems:  A or B
     Access Overload Class:  XX
           Group ID Format:  XX

    Initial Paging Channel:  333 or 334
             Station Class:  00

                Horn Alert:  F + #(Aux)
           New Unlock Code:  NAM
             System Select:  F + 1 + X
                               X=1  (A then B)
                               X=2  (B then A)
                               X=3  (A only)
                               X=4  (B only)
                               X=5  (Home)

                              ALPINE 9511

                 NAM Type:  EEPROM
             Manufacturer:  Fujitsu
               Programmer:  Handset
           ESN Prefix DEC:  150
                      HEX:  96
  ESN, S/N Match Required:  Yes
     Programmable Handset:  Yes
       Available Channels:  832

     Programming Sequence:  Power On
                            F + LOCK
                            POWER OFF
                            POWER ON
                            #626#7764726 (within 10 seconds)
                            HOLD (*) key until tone stops
                            Enter Data for each step then press STOR
                            Press SEND to write data

                         #Digits
         System ID Format:  5     XXXXX
         Local Use Option:  1     1
               MIN Option:  1     1
            Mobile Number:  10    XXX-XXX-XXXX
            Station Class:  2     08
   Initial Paging Channel:  3     333 or 334
    Access Overload Class:  2     XX
         Preferred System:  1     0 (B) or 1 (A)
          Group ID Format:  2     XX
                     Lock:  3or4  XXX or XXXX
               Call Timer:  1     4 (see i)
                Auto Lock:  1     1 (see ii)
         Call Restriction:  1     1 (see iii)

                                i. Call Timer - 1  Timer off
                                                2  6-seconds
                                                3  30-seconds
                                                4  60-seconds
  
                                ii. Auto Lock - 1  Manual Lock, No out
                                                2  Manual Lock, No calls
                                                3  Auto Lock, No out
                                                4  Auto Lock, No calls

                        iii. Call Restriction - 1  No Restriction
                                                2  No Memory Dialing
                                                3  No Long Distance
                                                4  Both 2 and 3
                                                5  Memory Calls only
                                                   ALPINE 9511   NAMS 2,3,4

    Programming Sequences:  Power On
                            Unlock Power (if locked)
                            (F) (7) (NAM Number - 2, 3, or 4)
                            (F) (Lock)
                            Power Off
                            Power On
                            Follow Programming Code and Steps from Top Model

               Horn Alert:  F + # (Aux)
          New Unlock Code:  NAM
            System Select:  F + 1 + X
                              X=1  A then B
                              X=2  B then A
                              X=3  A only
                              X=4  B only
                              X=5  Home

                              ALPINE 9525 and 9530

                 NAM Type:  EEPROM
             Manufacturer:  Fujitsu
               Programmer:  Handset
           ESN Prefix DEC:  150
                      HEX:  96
  ESN, S/N Match Required:  Yes. Manufacturer Prefix + Last 4 or 5 digits
     Programmable Handset:  Yes
       Available Channels:  832

     Programming Sequence:  Power On
                            F + LOCK
                            Power Off
                            Power On
                            # + 626 + # + 7764726 (within 10 seconds)
                            Hold (*) key until tone stops
                            Enter data for each step then press STOR
                            Press SEND to write data

                        # of Digits
         System ID Format:  5     XXXXX
         Local Use Option:  1     1
               MIN Option:  1     1
            Mobile Number:  10    XXX-XXX-XXXX
            Station Class:  2     08 (Mobile) or 14 (Portable)
   Initial Paging Channel:  3     333 or 334
    Access Overload Class:  2     XX
         Preferred System:  1     1(A) or 0(B)
          Group ID Format:  2     XX
              Unlock Code:  3or4  XXX or XXXX
               Call Timer:  1     4 (i)
                Auto Lock:  1     1 (ii)
         Call Restriction:  1     1 (iii)
      System ID Inhibit #:  5     XXXXX
      System ID Inhibit #:  5     XXXXX
      System ID Inhibit #:  5     XXXXX

                         i. Call Timer Increment -  1 Timer Off
                                                    2  6-seconds
                                                    3  30-seconds
                                                    4  60-seconds

                        ii. Auto Lock -  1 Manual Lock, no out
                                         2  Manual Lock, No calls
                                         3  Auto Lock, No out
                                         4  Auto Lock, No calls

                       iii. Call Restriction -  1 No Restriction
                                                2  No Memory Dialing
                                                3  No Long-Distance
                                                4  Both 2 and 3
                                                5  Memory Calls only

NAMS 2-4

     Programming Sequence:  Power On
                            Unlock Power (if locked)
                            F + 7 + NAM 2, 3 or 4
                            F + LOCK
                            Power Off
                            Power On
                            Follow Programming Code and steps from top example.

                              ALPINE 9550 Portable

                 NAM Type:  EEPROM
             Manufacturer:  Fujitsu
               Programmer:  Handset
           ESN Prefix DEC:  150
                      HEX:  96
  ESN/Serial Number Match:  Yes. Manufacturer prefix + last 4 or 5 digits
     Programmable Handset:  Yes
       Available Channels:  832
     Programming Sequence:  Power On
                            F + Lock
                            Power Off
                            Power On
                            # + 626 + # + 7764726 (within 3 seconds)
                            Hold (*) key until tone stops
                            Enter data for each step then press STOR
                            Press SEND to write data

                         # digits
         System ID Format:  5     XXXXX
         Local Use Option:  1     1
               MIN Option:  1     1
            Mobile Number:  10    XXX-XXX-XXXX
            Station Class:  2     14
   Initial Paging Channel:  4     0333 or 0334
    Access Overload Class:  2     XX
         Preferred System:  1     1(A) or 0(B)
          Group ID Format:  2     XX
              Unlock Code:  3or4  XXX or XXXX
               Call Timer:  1     4(i)
                Auto Lock:  1     1(ii)
         Call Restriction:  1     1(iii)

                         i. Call Timer Increment -  1 Timer Off
                                                    2  6-seconds
                                                    3  30-seconds
                                                    4  60-seconds

                        ii. Auto Lock -  1  Manual Lock, no out
                                         2  Manual Lock, No calls
                                         3  Auto Lock, No out
                                         4  Auto Lock, No calls

                       iii. Call Restriction -  1  No Restriction
                                                2  No Memory Dialing
                                                3  No Long-Distance
                                                4  Both 2 and 3
                                                5  Memory Calls only

     Programming Sequence:  Power On
                            Unlock Phone (if locked)
                            F + 7 + NAM 2, 3 or 4
                            F + LOCK
                            Power Off
                            Power On
                            Follow Programming Code and steps from above

          New Unlock Code:  NAM
            System Select:  FCN + 1 + X
                             X=1  AB
                             X=2  BA
                             X=3  A only
                             X=4  B only
                             X=5  Home

Curent status may be reviewed with RCL/ALT + FCN + 1