              NOVELL TECHNICAL INFORMATION DOCUMENT

TITLE:              Client API for Assembly Documentation Update
DOCUMENT ID:        TID100075
DOCUMENT REVISION:  A
DATE:               04FEB94
ALERT STATUS:       Yellow
INFORMATION TYPE:   Issue
README FOR:         NA

NOVELL PRODUCT and VERSION:
NetWare Client SDK 1.0e

ABSTRACT:

This document contains the latest corrections and updates for the
Client API for Assembly documentation.

------------------------------------------------------------------
DISCLAIMER
THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO
NOVELL.  NOVELL MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY
THIS INFORMATION.  HOWEVER, THE INFORMATION PROVIDED IN THIS
DOCUMENT IS FOR YOUR INFORMATION ONLY.  NOVELL MAKES NO EXPLICIT
OR IMPLIED CLAIMS TO THE VALIDITY OF THIS INFORMATION.
------------------------------------------------------------------

ISSUE

     This file contains the latest changes and additions to the
     Client API for Assembly version 1.0.

     NetWare Client API for Assembly Errata - Last updated
     02-03-94
     -----------------------------------------------------
     ***

     Cancel LPT Capture                               02-03-94

     The DL register should contain 02h on entry.  Ignore the
     line about the DH register.  This call ends a capture on the
     default LPT device instead of on a specified device.

     ***

     End LPT Capture                                  02-03-94

     The DL register should contain 01h on entry.  Ignore the
     line about the DH register.  This call ends a capture on the
     default LPT device instead of on a specified device.

     ***

     Flush LPT Capture                                02-03-94

     The DL register should contain 03h on entry.  Ignore the
     line about the DH register.  This call closes the capture
     file on the default LPT device instead of on a specified
     device.

     ***

     Flush Specific LPT Capture                       02-03-94

     This call is missing from the documents; however, "Flush LPT
     Capture" actually has the documentation for "Flush Specific
     LPT Capture."

     ***

     Start LPT Capture                                02-03-94

     The DL register should contain 00h on entry.  Ignore the
     line about the DH register.  This call starts a capture on
     the default LPT device instead of on a specified device.

     ***

     Map Directory Number to Path                     02-03-94

     The parameter at offset 4 of the request packet should read
     as follows:

     Offset  Request Packet Contents  Bytes  Remarks

     4       Directory Entry          4      Index to File
                                             Server's directory
                                             tables.  Must be
                                             associated with
                                             volume number.

     ***

     Scan Property                                    02-03-94

     The parameter at offset 18 of the reply packet should be 4
     bytes long, not 2.  The following is an example of how the
     end of the reply buffer should look:

               Reply Packet
     Offset     Contents          Bytes       Remarks

     18      Search Instance        4    Use to increment last
                                         instance on iterative
                                         calls.

     22      Value Available Flag   1    00h = Property has no
                                               value.

                                         FFh = Property has a
                                               value.

     23      More Properties Flag   1    00h = Last property

                                         FFh = More properties