              NOVELL TECHNICAL INFORMATION DOCUMENT

TITLE:              IBM Token-Ring v2.63 Workstation Drivers
DOCUMENT ID:        TID015502
DOCUMENT REVISION:  A
DATE:               28MAR94
ALERT STATUS:       Yellow
INFORMATION TYPE:   Symptom Solution
README FOR:         TOKWS.EXE

NOVELL PRODUCT and VERSION:
NetWare Client for DOS/MS Windows Pre 1.1

ABSTRACT:

Novell strongly recommends that ODI drivers be used instead of the drivers
included with this file.  See DOSUPx.EXE where x is a alphanumeric character
(0-F), such as DOSUP7.EXE for latest DOSODI drivers. (DOSUPX.EXE is a
distribution file.)  TOKWS.EXE contains IBM Token-Ring v2.63 workstation
drivers.


DISCLAIMER
THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL.  NOVELL
MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY THIS INFORMATION.  HOWEVER, THE
INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION ONLY.  NOVELL
MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS INFORMATION.


SYMPTOM

     Users need an IPX.COM generated for the IBM Token-Ring v2.63 workstation
     drivers

SOLUTION

     Apply the files found in the TOKWS.EXE file.

     Two DIFFERENT IPX.COM files can be generated with the STOKEN and SLANSUP
     drivers.

     These two IPX.COM files are described in CASE 1 and CASE 2:

     CASE 1:   IPX.COM   (IPX.OBJ generated and linked with SLANSUP.OBJ)

          This is the LAN Support driver.  To work properly, this driver
          requires the IBM LAN Support drivers, and it will not work without
          them.  This IPX.COM requires that the following IBM LAN Support
          files to be specified in the workstation's CONFIG.SYS file:

          device = DXMA0MOD.SYS    (5C arbitrator)
          device = DXMC0MOD.SYS    (adapter interface)
          device = DXMT0MOD.SYS    (optional IBM Netbios driver)

          This IPX.COM driver also supports Remote Program Loading.


     CASE 2:   IPX.COM   (IPX.OBJ generated and linked with STOKEN.OBJ)

     This is the NATIVE Token-Ring driver.  It communicates directly to the
     Token-Ring adapter.  This IPX.COM driver works exactly opposite of the
     IPX.COM file mentioned in CASE 1.  This IPX.COM file works without IBM
     LAN Support drivers being specified in the workstation's CONFIG.SYS.

     When using this IPX.COM, the workstation's CONFIG.SYS must not include
     IBM LAN Support driver specifications.  This IPX.COM file supports Remote
     Program Loading.

     Self-Extracting File Name:  TOKWS.EXE     Revision:  A

     Files Included     Size     Date      Time

     \
        TOKWS.TXT         (This File)
       STOKEN.LAN        105   10-15-91   12:16p
       STOKEN.OBJ       6683   08-23-91    9:12a
      SLANSUP.LAN        122   02-03-92    3:33p
      SLANSUP.OBJ       6080   10-18-91    6:24a

     Installation Instructions:

     *************************************************************
     IMPLEMENTATION of SLANSUP.OBJ and STOKEN.OBJ
     *************************************************************

     1.   Determine which IPX.COM to create, LAN Support Token-Ring or Native
          Token-Ring.

     2.   Copy the corresponding .lan files to the SHGEN or WSGEN directory or
          diskette and the corresponding .obj files to the LAN_DRV_001
          diskette.

     3.   Generate the new IPX.COM with SHGEN or WSGEN.

     4.   Configure the IPX.COM at the command line based on your needs using
          the following instructions:

     LAN SUPPORT IPX.COM  (IPX.OBJ generated and linked with SLANSUP.OBJ)
     ========================================================

     IPX.COM - This is a Client IPX Driver for the IBM Token-Ring generated
     with the IBM LAN Support Program.  It works with ROUTE.COM when Source
     Routing is REQUIRED.  This version of IPX.COM can be configured by typing
     the following parameters at the command line (or batch file) when it is
     loaded:

     CONFIGURING the DOS Workstation's IPX.COM (LAN Support):
     ========================================================

     IPX.com - (IPX.obj linked with SLANSUP.obj) can be configured by typing
     in the following parameters when it is loaded:

     IPX o,ALT/PRI,ls=nn,mem=xx00,node=xxxxxxxx,ntb=nn,saps=nn,tbz=nnnn

          where:

          o

               (lowercase letter "o")  This letter is required to override the
               SHELL.CFG file.

          ALT

               ALT configures the driver as the ALTERNATE adapter.

          PRI

               PRI configures the driver as the PRIMARY adapter -- this is the
               default.

          ls=nn

               nn is a DECIMAL number specifying the number of LINK Stations
               that the driver should allocated when initializing.  The
               DEFAULT is 00.

          mem=xx00

               The xx00 is a HEXADECIMAL address of where shared RAM is
               located.

               The default is D800 for PRIMARY and D400 for ALTERNATE.

               This setting always gets overridden by a Microchannel Reference
               mem setting; microchannel machines have this ability in the
               machine reference.  However, ISA bus machines must use this
               driver's setting because there is no other way to specify it
               except with this driver's "mem=xx00" setting.

          node=xx

               The xx is up to a 4 byte (8 hex digits) HEXADECIMAL number
               specifying a LAA (locally administered node address), which
               overrides the hardware's default Node Address.  The hardware's
               node address is known as a universally administered address. 
               4000h will be prefixed to this number to form a 6 byte NODE
               address: 4000 xxxx xxxx.  If a LAA is specified in the
               CONFIG.SYS as follows:

                    device=dxmc0mod.sys 4000xxxxxxxx

               device=dxmt0mod.sys o=n, The o=n means do not open adapter and
               IPX.COM opens the adapter, then this node ID must also be
               specified with "IPX o,pri,node=xxxxxxxx" when IPX.COM loads.

          ntb=nn

               The nn is a DECIMAL number specifying the NUMBER of TRANSMIT
               BUFFERS to allocate.  The default is one.  Specifying two may
               help performance on some of the new IBM Token-Ring Cards.

          saps=nn

               The nn is a DECIMAL number specifying the number of SAP
               stations that the driver should allocated when initializing. 
               The driver will increment nn by one, because NetWare requires 1
               SAP.  The default is one.

          tbz=nnnn

               The nnnn is a DECIMAL number specifying the size of the
               Transmit buffer.  It can be any number between 512 and 4202. 
               The driver will adjust it to the nearest power of two plus 106
               bytes of overhead.  The default is 1024 (1130).

          All these parameters are separated by commas or blanks, are
          optional, are not case sensitive, and may be entered in any order.


     NATIVE TOKEN-RING  IPX.COM  (IPX.OBJ generated and linked with
     STOKEN.OBJ)
     ========================================================

     IPX.COM - This is a native Token-Ring driver for the DOS workstation.  It
     does not require the IBM LAN Support Program.  It is faster and smaller
     than LAN Support IPX.COM.  It works with ROUTE.COM if Source Routing is
     required. Its default Transmit Buffer Size is 4096 (4 KB) for the 16/4
     MBps adapters, 2048 for the 8-bit, 4 MBps long card.  This version of
     IPX.COM can be configured by typing the following parameters at the
     command line (or batch file) when it is loaded:

     IPX.COM (IPX.OBJ generated and linked with STOKEN.OBJ) can be configured
     by typing the following parameters when it is loaded:

          IPX o,ALT/PRI,mem=xx00,node=xxxxxxxx,slot=n,tbz=nnnn

          where:

          o

               (lowercase letter "o")  This letter is required to override the
               SHELL.CFG file.

          ALT

               ALT configures the driver as the ALTERNATE adapter.

          PRI

               PRI configure the driver as the PRIMARY adapter.  PRI is the
               default.

          mem=xx00

               The xx00 is a HEXADECIMAL address of where shared RAM is
               located.  The default is D800 for PRIMARY and D400 for
               ALTERNATE.  Microchannel machines already set this mem address
               in the MACHINE REFERENCE, and the machine reference setting
               always overrides any "IPX o,PRI/ALT,mem=xx00" driver setting. 
               ISA bus adapters must be set with this driver's "mem=xx00"
               setting because there is no other way.

          node=xx

               The xx is HEXADECIMAL Number up to an 4 byte that specifies the
               Node Address.  4000h will be prefixed to this number to form a
               6 byte NODE Address: 4000xxxxxxxx.

          slot=n

               The n is a DECIMAL number specifying the MICROCHANNEL slot
               number where the board is located.  It is only valid if on a
               Microchannel machine.

          tbz=nnnn

               The nnnn is a DECIMAL number specifying the size of the
               Transmit buffer.  It can be any number between 512 and 4202. 
               The driver will adjust it to the nearest power of two plus 106
               bytes of overhead.  The default is 4096 (4202).

     All parameters are separated by commas or blanks, are optional, are not
     case sensitive, and may be entered in any order.

     Patch History:

     NOTE:     Version 2.63 of SLANSUP.OBJ is the latest version that has been
               through software test.  The most common problem with
               SLANSUP.OBJ version 2.62 is the workstation that will
               occasionally hang when loading IPX.COM especially when
               broadcast traffic exists on the ring.

     04-29-91

          This version contained the initial release of TOKWS.DOC and
          TOKWS.ZIP.

     11-11-91

          This version updated the STOKEN.OBJ to version 2.63.  It added a
          note about SLANSUP.OBJ.

     05-27-92

          This version updated the SLANSUP.OBJ from version 2.62 to version
          2.63. (revised note about SLANSUP.OBJ and explained a common problem
          with 2.62 SLANSUP.OBJ.