Special Function Register Bits ... 8052.  *TMOD, PCON not bit-addressible.
 P1:    *    *    *     *     *     *     T2EX  T2
 P3:    RD   WR   T1    T0    *INT1 *INT0 TXD   RXD
 PSW:   CY   AC   F0    RS1   RS0   OV    *     P
 IE:    EA   *    ET2   ES    ET1   EX1   ET0   EX0
 IP:    *    *    PT2   PS    PT1   PX1   PT0   PX0
 TCON:  TF1  TR1  TF0   TR0   IE1   IT1   IE0   IT0
 T2CON: TF2  EXF2 RCLK  TCLK  EXEN2 TR2   C/*T2 CP/*RL2
 SCON:  SM0  SM1  SM2   REN   TB8   RB8   TI    RI
*TMOD:  M0   M1   C/*T1 GATE1 M0    M1    C/*T0 GATE0
*PCON:  SMOD *    *     *     GF1   GF0   PD    IDL

Enables Priorities Flags Pins  Control/Status Bits  Interrupt
EA
   EX0     PX0      IE0  *INT0      (IT0)           External 0
   ET0     PT0      TF0  (T0)   (TR0, TMOD[0-3])    Timer 0
   EX1     PX1      IE1  *INT1      (IT1)           External 1
   ET1     PT1      TF1  (T1)   (TR1, TMOD[4-7])    Timer 1
   ES      PS                   (SM0, SM1, SMOD)    Serial
                    TI   TXD    (TCLK, TB8)            Transmit
      REN           RI   RXD    (RCLK, SM2, RB8)       Receive
   ET2     PT2      TF2  (T2)    (TR2, C/*T2)       Timer 2
      EXEN2         EXF2 T2EX     (CP/*RL2)         Capture Register 2

General Status Flags: CY, AC, OV, P
General Control Flags: RD, WR, RS1, RS0, PD, IDL
    PD, IDL are in the PCON register and are not individually addressible.
General purpose flags: F0, GF1, GF0

Interrupt conditions:
IEn: Interrupt on EA & EXn.
     Falling edge on *INTn, if ITn = 1
     Low level on *INTn, if ITn = 0
TFn: Interrupt on EA & ETn, on overflow from TIMERn.
TIMERn gets its input as follows:
   TRn & (GATEn  & INTn | ~GATEn)
   C/*T = 1: From Tn ..... COUNTER MODE
   C/*T = 0: From OSC .... TIMER MODE
TIMERn overflows/counting limits:
   M1:M0 = 0:0 -- 13-bit timer
   M1:M0 = 0:1 -- 16-bit timer
   M1:M0 = 1:0 -- TLn 8-bit timer, THn 8-bit reload
   M1:M0 = 1:1 -- TL0 8-bit under TIMER0
                  TH0 8-bit under TIMER1 (TIMER MODE only, TR1, TF1 used)
                  TL1, TH1: free for other use (as baud rate timer)
RI: Interrupt on EA & ES & REN.
    SM2 = 1: By valid stop bit (mode 0), or 9th bit (modes 2, 3) (RB8 = 1)
    SM2 = 0: On receipt of any stop bit.
TI: Interrupt on EA & ES.
Baud rates:
   SM0:SM1 = 0:0 ... OSC/12.  No timers.  SM2 = 0
                     This mode is used for SYNCHRONOUS communications.
   SM0:SM1 = 1:0 ... 2^SMOD * OSC/64.
   SM0:SM1 = *:1 ... TIMER1: 2^SMOD * OSC/12 / (32*(256 - TH1))
                     TIMER2: OSC/(32*(65536 - RCAP2))
Baud rate timer:
   For reception ...... TImer 1 if RCLK = 0
                        Timer 2 if RCLK = 1
   For transmission ... TImer 1 if TCLK = 0
                        Timer 2 if TCLK = 1
Data bits:
   SM0:SM1 = 0:* ... 8 bits.
   SM0:SM1 = 1:* ... 9 bits.

TF2: Interrupt on EA & ET2, on overflow from TIMER2.
EXF2: Interrupt on EA & ET2 & EXEN2 on falling edge of T2EX.
TIMER2 gets its input as follows:
   TR2
        C/*T2 = 1: On falling edge of T2 ... COUNTER MODE
        C/*T2 = 0: From OSC ................ TIMER MODE
Capture 2 works as follows:
        CP/*RL2 = 1: Loads TIMER2 -> RCAP2
        CP/*RL2 = 0: Loads RCAP2 -> TIEMR2