           UNIDEN CP-900, 1000, 1050, 1100, 1200, 1500, 1900, 2000,
                    3000, PRESIDENT 4000 GTS and 4500 GTS
-------------------------------------------------------------------------------
                NAM Type:  EEPROM
            Manufacturer:  UNIDEN
              Programmer:  Serivce Handset or Programmer Handset
          ESN Prefix DEC:  172
                     HEX:  AC
 ESN, S/N Match Required:  Yes
    Handset Programmable:  Service Handset or Programmer Handset
      Number of Channels:  666 (900, 1000) others 832

    Programming Sequence:  Connect antenna or load
                           Power Off
                           Disconnect standard handset
                           Connect blue or white service handset
  White Handset (CP-010):  Turn Power Switch On while holding *
                            and # continue holding * and # for two seconds
    Blue Handset(CP-210):  Turn Power Switch On
                           Press SELECT + 2 + SEND
           Both Handsets:  Enter step number, then data for individual
                            parameter
                           Press STO to enter data for each step
                           Increment by pressing next step number
  To review parameters press:  RCL + Step number + STO (to exit)
                           If phone has dual NAM(ie 1050, 1500 & 2000),
                           Press 9 + 5 + SEND (to toggle between NAMs)
                           Press SEND to write NAM information
                           PASS will appear in display if data is valid

Step                  # of Digits
0              System ID:  5    XXXXX + STO
1              Local Use:  1    (0 or 1) + STO
2                MIN Opt:  1    (0 or 1) + STO
3          Mobile Number:  10   XXX-XXX-XXXX + STO
4    Initial Paging Chan:  3    (333 or 334) + STO
5        Access Overload:  2    XX + STO
6       Preferred System:  1    [0 (B) or 1 (A)] + STO
7               Group ID:  2    XX + STO
8         Local Code (1):  4    XXXX + STO
9       F5 DTMF Duration:  2    0-100ms or 1-Continous

Press STO to increment to F6 or A

All models Except 1500, 1900 and 4500 GTS

      F6 Automatic Power:  1    0=3 hrs or 1=6 hrs

A  Handset/Handsfree 1
 0(phone auto transfers from switching H/S to H/F) OR
 1(call ends when H/S is placed in cradle unless user presses
   RCL + 6 + 6)

Press STO after entering F6 or A data
Press SEND to exit program mode

              Horn Alert:  RCL + 9 + 9 + Turn Ignition Off

         New Unlock Code:  NAM

           System Select:  X + STO + 8 + 8
                                 X=1  A only
                                 X=2  B only
                                 X=3  Home
                                 X=4  Standard AB or BA
                                 X=5  Inverted BA or AB

-------------------------------------------------------------------------------
                      UNIDEN 5000 and 6000 GTS Portable
-------------------------------------------------------------------------------
                NAM Type:  EEPROM
            Manufacturer:  UNIDEN
              Programmer:  Program or Service Handset with CP 505 Adaptor
          ESN Prefix DEC:  172
                     HEX:  AC
 ESN, S/N Match Required:  Yes
    Stamped Model Number:  5000 or 6000 GTS
      Number of Channels:  832

    Programming Sequence:  Power Off
                           Remove Battery and install CP505 or CP505A adaptor
                           Connect CP505(A) to power supply or to CP
                            504 battery eliminator per adaptor instructions
                           Connect Program Handset to CP 505(A) adaptor
  White Handset (CP-010):  Turn Power Switch On while holding *
                            and # continue holding * and # for two seconds
    Blue Handset(CP-210):  Turn Power Switch On
                           Press SELECT + 2 + SEND
           Both Handsets:  Enter step number, then data for individual
                            parameter
                           Press STO to enter data for each step
                           Increment by pressing next step number
 To review parameters press:  RCL + Step number + STO (to exit)
                           To select Alternate NAM, Press 1 + STO + 90 (NAM 1)
                            or 2 + STO + 90 (NAM 2)
                           Press SEND to write NAM information
                           PASS will appear in display if data is valid

 Step                 # of Digits
 0             System ID:  5    XXXXX + STO
 1             Local Use:  1    (0 or 1) + STO
 2               MIN Opt:  1    (0 or 1) + STO
 3         Mobile Number:  10   XXX-XXX-XXXX + STO
 4  Initial Page Channel:  3    (333 or 334) + STO
 5       Access Overload:  2    XX + STO
 6      Preferred System:  1    [0 (B) or 1 (A)] + STO
 7              Group ID:  2    XX + STO
 8         Lock code (1):  4    XXXX + STO
 9  Options F5 DTMF
                Duration:  1    0 - Continuous
                                1 - 100 ms

Press STO to program phone

         New Unlock Code:  RCL + 70 + Current 4 digit Unlock code
                            + new 4 digit Unlock code

           System Select:  X + STO + 8 + 8
                            X=1  A only
                            X=2  B Only
                            X=3  Home
                            X=4  Standard AB or BA
                            X=5  Inverted BA or AB

-------------------------------------------------------------------------------
                           UNIDEN CP-5500 Portable
-------------------------------------------------------------------------------
                NAM Type:  EEPROM
            Manufacturer:  UNIDEN
              Programmer:  Keypad
          ESN Prefix DEC:  172
                     HEX:  AC
 ESN, S/N Match Required:  Yes
    Stamped Model Number:  CP-5500
      Number of Channels:  832

    Programming Sequence:  Install fully charged battery
                           Power On
                           Select NAM
                                  NAM 1:  1 + STO + 90
                                  NAM 2:  2 + STO + 90
                           Power Off
                           Press PWR key while holding * and #
                           Continue holding * and # for four seconds
                            "Roam.No Svc.In Use& M" lights will display
                           Release * and # keys
                           Enter sequence 32218591 (within 7 seconds)
                            SID will display
                           Enter Step number, then data for individual
                            parameter
                           Press STO to enter data for each step
                            (ie to enter System ID, press 0+XXXXX+STO)
                           Increment by pressing next step number
 To review parameters press:  RCL + step number
                            + STO (to exit)
                           Press SEND to write NAM information
                           PASS will appear in display if data is valid
                           Press END to exit program mode

Step                  # of Digits
0              System ID:  5    XXXXX + STO
1              Local Use:  1    (0 or 1) + STO
2                MIN Opt:  1    (0 or 1) + STO
3          Mobile Number:  10   XXX-XXX-XXXX + STO
4   Initial Page Channel:  3    [333 or 334] + STO
5        Access Overload:  2    XX + STO
6       Preferred System:  1    [9 (B) or 1 (A)] + STO

Note 1:  Step number will not display when entering mobile number)

7               Group ID:  2    XX + STO
8              Lock Code:  4    XXXX + STO
9          DTMF Duration:  1    0 - 100 ms or
                                1 - Continuous

Press STO after entering Step 9
Press SEND to write data
Press END to exit program mode

        New Program code:  RCL + 70 + Current 4-digit Program Lock
                            Code (Preset 0000) + new 4 digit program
                            code + STO + END
         New Unlock Code:  RCL + 70 + 4 digit program Lock Code
                            (Preset 0000) + SEND + New 4 digit Unlock Code
                            (Preset 0123) + STO + END

           System Select:  X + STO + 8 + 8
                                 X=1  A Only
                                 X=2  B Only
                                 X=3  Home
                                 X=4  Standard AB or BA
                                 X=5  Inverted BA or AB
                                 X=6  System ID (*)

    (*) To set System ID:  CLR + 5 digit System ID + STO + 72

To view current System Select Setting:  RCL + 88
