ey Entry Function Name Remarks ========= ============= ======= RCL, #, 01 SUSPEND All dots come on (not on Modified test chip) It terminates the normal mode, performs initialization and awaits further test commands. RCL, #, 02 RESTART It teminates the test mode, enters the normal mode and restarts the call processing tasks. You hear a wake-up tone and momentarily the phone number appears on the display. You are now at receiving standby mode (normal mode). RCL, #, 03 STATUS It shows the status information of the unit by 16 digits on the display. ---------- ---------- Example: 119110 AAABCD 0003100363 EFGHIJKKKK ---------- ---------- Where: AAA: Shows RSSI (Receiver Signal Strength) Value ranging from 000 through to 255 (3 digits). B: Shows RXM (Receiver Audio Mute) or Receiver audio gate on/off. 1 = muted or gate off. C: Shows TXM (Transmitter Audio Mute) or Transmitter audio gate on/off. 1 = muted or gate off. D: Shows WS (Word Synchronization) in FOCC. 1 =WS acquired. E: Shows B/I (Current state of the busy idle bit of FOCC). 1 = idle 0 = busy. F: Shows CARR (carrier) on/off. 1 = off. G: Shows ST (Signalling Tone) on/off. 1 = ST on. H: Shows SAT (Supervisory Audio Tone) on/off. 0 = 5970Hz, 1 = 6000Hz, 2 = 6030Hz and 3 = No SAT. I: Shows MODE. 1 = Control channel, 0 = Voice channel. J: Shows Transmission Power Reduction Level. 0 = No reduction. 1 = No reduction. 2 = No reduction. 3 = -4dB. 4 = -8dB. 5 = -12dB. 6 = -16dB. 7 = -20dB. KKKK: Shows Channel Number, ranging from 0000 through 0600 & 1329 through 2047 (4 digit). RCL, #, 04 RESET Reset the autonomous timer to zero. RCL, #, 06 INIT Initialize the transceiver unit to the following state; Carrier off. Attenuation 0dB. Receiver-Audio muted. Transmit-Audio muted. Signaling Tone (ST) off. Autonomous timer reset and it's periodic. SAT off. DTMF and Audio tones off. Received-voice Volume Max. Compandor off. RCL, #, 07 CARRIER-ON Turn the TX carrier on. RCL, #, 08 CARRIER-OFF Turn the TX carrier off. RCL, #, 09 LOAD-SYNTH Set the synthesizer to the channel specified by up to 4 digits followed by # key (up to 4 digits = 0 through 600, 1329 through 2047). --------- --------- Example: TEST MODE TEST MODE Pressing 333 and # 09- 09-333 --------- --------- RCL, #, 10 SET-ATTN Set the RF power attenuation to the value specified by 1 digit followed by the # key (1 digit = 0 through 7). ---------- Example: TEST MODE Pressing 4 for 8dB reduction 10-4 ---------- 0 to 2 = No reduction. 3 = -4dB, 4 = -8dB, 5 = -12dB, 6 = -16db, 7 = -20dB. RCL, #, 11 RXMUTE Mute the receive-audio signal. No audio signal comes from the speaker. RCL, #, 12 RXUNMUTE Unmute the receive-audio signal. Noise or Voice comes from the speaker. RCL, #, 13 TXMUTE Mute the Transmit-audio signal. RCL, #, 14 TXUNMUTE Unmute the Transmit-audio signal. RCL, #, 15 RESET OFF Discontinue periodic resetting of the autonomous timer (allow timer to time out). RCL, #, 16 STON Transmit a continuious Signalling Tone (ST). RCL, #, 17 STOFF Stop transmission of Signalling Tone (ST). RCL, #, 23 VERSION Show the software version-information on the display. ---------- V-2.0 (V-9011) ---------- RCL, #, 24 READ SN Show the production serial number of the phone. i.e. ---------- Serial No. 22A-000001 ---------- RCL, #, 32 SATON Enable the transmit of SAT. One digit follow- -ing the command code shall contain the color code of the SAT frequency that the transceiv- -er unit may expect to receive. SAT shall be transmitted if the carrier is currently on. COLOR CODE DIGIT. SAT FREQUENCY. ================= ============== 0 5970Hz 1 6000Hz 2 6030Hz RCL, #, 33 SATOFF Disable the transmission of SAT. RCL, #, 34 CDATA Transmits 6 bytes NAM data as 240 bits data. DEFAULT = 01, 02, 03, 04, 05, 06 (No TX ON). RCL, #, 35 HIGH TONE ON Activate the high audio tone (1150 Hz) and apply it to the receive-audio line. You hear the high tone from the speaker. RCL, #, 36 HIGH TONE OFF Deactivate the high audio tone. Tone stops. RCL, #, 37 LOW TONE ON Activate the low audio tone (770Hz) and apply it to the receive-audio line. You hear the low tone from the speaker. RCL, #, 38 LOW TONE OFF Deactivate the low audio tone. Tone stops. RCL, #, 39 INVM Initialize non-volatile memory. Set registra- -tion memory and clear all the speed-dial memories. Set the Lock State to activate (Fully Locked). RCL, #, 42 DTMF ON It sounds DTMF tones, a responce from each pressed key. It sends the signal to RX AUDIO and TX AUDIO lines. RCL, #, 43 DTMFOFF Deactivates DTMF generator. DTMF tones stop. RCL, #, 48 TONE-OFF Deactivate alert tone and external call alert. The alert tones stop. RCL, #, 49 TX-DISE Deactivate TX ENABLE line. Disable the transmitter. RCL, #, 50 STATUS REPEAT Status Repeat at Test Mode. (TEST MODE) RCL, #, 51 MON Monitors the port status. " ABCD" (Mid line of LCD display). A: HOOK 1 = ON HOOK B: EXT PS 1 = BATTERY MOUNTED C: ADP MON 1 = ADAPTER CONNECTED D: HF MON 1 = HANDS FREE RCL, #, 57 TX-ENABLE Activate TX ENABLE line. Enable transmitter. RCL, #, 60 AUDIO PATH Set the Audio Path. " 60-X" (Mid line of LCD display). X: 0 = HF 1 = SPK 2 = ALT 3 = HS RCL, #, 61 STATUS-REPEAT Without suspend. It shows the status information of the unit by 16 digits every second. ---------- ---------- Example: TEST MODE TEST MODE Press 1 and # for display on. 61- 61-1 Press 0 and # for display off. ---------- ---------- After the setting, press RCL, #, 02. The wake-up tone and display come on. The 16 digit status information appears. ---------- ---------- Example: 119110 AAABCD 0003100363 EFGHIJKKKK ---------- ---------- Where: AAA: Shows RSSI (Receiver Signal Strength) Value ranging from 000 through to 255 (3 digits). B: Shows RXM (Receiver Audio Mute) or Receiver audio gate on/off. 1 = muted or gate off. C: Shows TXM (Transmitter Audio Mute) or Transmitter audio gate on/off. 1 = muted or gate off. D: Shows WS (Word Synchronization) in FOCC. 1 =WS acquired. E: Shows B/I (Current state of the busy idle bit of FOCC). 1 = idle 0 = busy. F: Shows CARR (carrier) on/off. 1 = off. G: Shows ST (Signalling Tone) on/off. 1 = ST on. H: Shows SAT (Supervisory Audio Tone) on/off. 0 = 5970Hz, 1 = 6000Hz, 2 = 6030Hz and 3 = No SAT. I: Shows MODE. 1 = Control channel, 0 = Voice channel. J: Shows Transmission Power Reduction Level. 0 to 2 = No reduction. 3 = -4dB. 4 = -8dB. 5 = -12dB. 6 = -16dB. 7 = -20dB. KKKK: Shows Channel Number, ranging from 0000 through 0600 & 1329 through 2047 (4 digit). RCL, #, 69 SCAN SLOW Measure the Received Signal Stength Indicati- -on (RSSI) signal at each channel. Shows each channel number and it's RSSI level on the display. Example: ---------- ---------- TEST MODE TEST MODE Simply press # key or 69- 69-1 press channel number and #. ---------- ---------- To activate the SCAN SLOW command, press RCL. # 69, XXXX, #. Where XXXX = starting channel number (1 through 6000, 1329 through 2047). If you don't enter the channel number and press # key, then the channel will begin from 0001. The unit measures the RSSI at each channel, scanning from the channel number you set. The scanning speed is 0.5secs per channel. The unit shows each channel number and it's RSSI level on the display "XXXX-sss" (On Mid line). ---------- TEST MODE Where: XXXX = Channel number XXXX-sss sss = RSSI ---------- Pressing * key while scanning causes the unit to pause. Pressing * key again resumes scanning. To end scanning press the # key. The radio channel will be fixed at the first channel number and is ready to accept other commands. If you press other keys other than the * or # the unit ignores them and gives back a short alarm tone. RCL, #, 70 KEYPAD PROGRAM2 Allow you to do NAM programming via the keypad. See appendix C. RCL, #, 71 KEYPAD PROGRAM1 Allow you to do NAM programming via the Keypad. See appendix C. NOTE: This file contains the reference from Appendix A only. If you have or can get information from appendix C, please add it to the end of this file. RCL, #, 72 I/O DATA OUT Writes data (0-255) or I/O (0-127). Address is 00FF00H-0FF7FH XXX YYY (Mid Line) XXX = Address YYY = Write Data RCL, #, 73 AEC ON Turns AEC (Automatic Efficiency Control) on. RCL, #, 74 AEC OFF Turns AEC (Automatic Efficiency Control) off. RCL, #, 75 CDATA OFF Stops CDATA transmission. RCL, #, 77 LOAD SYNTH 2 CH assignation to TX/RX synth. "TXXXXRYYYY" (Mid Line). XXXX = TX channel YYYY = RX channel RCL, #, 78 SET DEFAULT DATA It writes default data into AF IC & EEPROM. RCL, #, 79 WRITE ADJUST DATA It writes to AF IC and EEPROM the adjust- (MAX DEV.) -ment data that specifies the MAX deviation for each unit. RCL, #, 80 WRITE ADJUST DATA It writes to AF IC and EEPROM the adjust- (EXT IN) -ment data that specifies the EXT IN data for each unit. RCL, #, 81 WRITE ADJUST DATA It writes to AF IC and EEPROM the adjust- (DTMF) -ment data that specifies the DTMF data for each unit. RCL, #, 82 WRITE ADJUST DATA It writes to AF IC and EEPROM the adjust- (MIC) -ment data that specifies the MIC data for each unit. RCL, #, 83 WRITE ADJUST DATA It writes to AF IC and EEPROM the adjust- (TX DATA) -ment data that specifies the TX data for each unit. RCL, #, 84 WRITE ADJUST DATA It writes to AF IC and EEPROM the adjust- (SAT) -ment data that specifies the SAT data for each unit. RCL, #, 85 WRITE ADJUST DATA It writes to AF IC and EEPROM the adjust- (RX DATA) -ment data that specifies the RX data for each unit. RCL, #, 86 WRITE ADJUST DATA Sets power level and specific data of each (POW LEVEL) unit in EEPROM with 7 byte.(P0-P7, Spec, Data). Specific Data: Fine adjustment of output power level. Example. RCL, #, 86, ___ #, ___ #. RCL, #, 87 WRITE DATA(RSSI) Writes A/D transformed data of +10dBuV to EEPROM to set at the position between block two and three of the RSSI indication. (between **--- and ***--). RCL, #, 88 MOD TRACKING ADJ VCO Modulation Senstivity. RCL, #, 90 BATT Shows the A/D converted value of the battery Voltage. " XXX" (Mid Line). XXX = 0 to 255. (0 = fucked!). RCL, #, 91 TEMP Shows the A/D converted value of the Temperature inside the unit. XXX = 0 to 255. (000 = fried!). RCL, #, 94 COMPANDOR ON Set the compandor circuit on. RCL, #, 95 COMPANDOR OFF Set the compandor circuit off. RCL, #, 99 KEYPADPROGC++ Write applications to run with the Intel 80386, 486 family of processors via the units keypad. Example: Write DOS and Windows applications in C++, write a Bluebox prog etc. Refer to the P3 C++ prog ref for further info also refer to DOS and Windows references. Note: This function only works with the P3 I/O card for connection to the CPU of a PC. Note: All information given in this file is from Appendix A of the P3 Test ROM manual, it is documented as per appendix A apart from the last couple of remarks under BATT and TEMP (i.e. Fucked! and Fried!) also the last test code 99 is a load of rubbish, well after writing all this long boring tech file about a phone that can do everything! I could resist added it! . Notes and Examples. =================== This section has been put here for you to add further notes about funtions you have found. Then please re-upload as next revision. ---------------------------------------------------------------------------- i.e. 1) Using the Phone capture other ID's. (I wish). by DREAMER. In test mode use RCL, #, 98 and take down all the information that pops up every second. *** Example only, put yours like this below ***. ---------------------------------------------------------------------------- *** addition *** PROGRAMMING THE NAM DATA ^^^^^^^^^^^^^^^^^^^^^^^^ In test mode, select RCL # 71 and follows steps below. Press # at the end of each step to continue. STEP KEY IN DISPLAY COMMENT 1 aaaaxxxxxx Phone No. aaaa is Provider Code eg 2344 and xxxxxx is last 6 digits of no. 2 bbbb Lock Code bbbb is 4 digit lock code. 3 zzzzz Home Area zzzzz = 02051 Vodafone zzzzz = 03600 Cellnet 4 1 or 0 System Sel. 1 = A Vodafone 0 = B Cellnet 5 xxxx System No. xxxx is 0836, 0831 etc for display purposes only 6 1 or 0 Roam. 1 = Yes 0 = No (usually NO) 7 1 or 0 Timer SW. 1 = Voice 0 = Callout (usually 1) 8 1 to 15 Priority High priority means better chance of call getting thru when cell is busy 9 1 or 0 Call Timer 1 = All calls 0 = Call Out only After all this has been entered, press # then hold down CLR until the display blanks. Enter RCL # 02 to reboot fone with new NAM settings in place. *** REQUEST TIME *** Would someone please explain how to program the other NAM section which is accessed in Test Mode by RCL #70, (eg SCM, FCN state etc etc ) and amend this file and u/l it again. Dr Bob 02/08/1995